Literature DB >> 20099071

Effect of sealants on laser fluorescence caries detection in primary teeth.

Elina Askaroglou1, Katerina Kavvadia, Panagiotis Lagouvardos, Lisa Papagiannoulis.   

Abstract

The aim of this study was to investigate in vitro the effects of clear or opaque sealants, on the laser fluorescence readings for occlusal caries detection in primary molars. For this reason, 427 occlusal sites in 199 teeth were clinically examined by one dentist, and their laser fluorescence (LF) was measured locally with the DIAGNOdent™ device, both before and after the teeth had been sealed with Delton Clear LC or Delton Opaque LC. For 29 of these teeth, we also measured the laser fluorescence by scanning the fissures before and after sealant application. We used Wilcoxon's signed ranks sum test and Spearman's rho correlation to compare and correlate the LF readings before and after sealing, while we used the Mann-Whitney U test to compare the two materials. Finally, we used the Kruskal-Wallis test to compare readings taken locally with those taken by the scanning technique. The results showed that there was an LF increase by a mean of 6 units after sealing with the clear material, while there was a 15 units decrease after sealing with the opaque one. LF readings before and after sealing correlated better for the clear material (rho = 0.826) than for the opaque one (rho = 0.507). LF readings were statistically significantly affected by both clear and opaque sealants (P < 0.001). However, this effect was statistically significantly less pronounced for the clear material (P < 0.001). There was also no difference between the LF readings taken by the fissure scanning technique or locally (P > 0.05). In conclusion, LF readings for occlusal caries detection in primary molars were significantly affected by both the clear and the opaque materials. However, the effect for the opaque material was more pronounced.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20099071     DOI: 10.1007/s10103-009-0745-5

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  31 in total

1.  Sealant use and placement techniques among pediatric dentists.

Authors:  R E Primosch; E S Barr
Journal:  J Am Dent Assoc       Date:  2001-10       Impact factor: 3.634

2.  Correlation between fissure discoloration, Diagnodent measurements, and caries depth: an in vitro study.

Authors:  Paola Francescut; Adrian Lussi
Journal:  Pediatr Dent       Date:  2003 Nov-Dec       Impact factor: 1.874

Review 3.  A systematic review of the performance of a laser fluorescence device for detecting caries.

Authors:  James D Bader; Dan A Shugars
Journal:  J Am Dent Assoc       Date:  2004-10       Impact factor: 3.634

4.  Clinical study on the effect of professional cleaning of occlusal tooth surfaces on laser fluorescence measurements.

Authors:  V Anttonen; L Seppä; H Hausen
Journal:  Caries Res       Date:  2005 Jul-Aug       Impact factor: 4.056

5.  Clinical evaluation of diagnodent in detection of occlusal caries in children.

Authors:  Aysegül Olmez; Dilek Tuna; Fatih Oznurhan
Journal:  J Clin Pediatr Dent       Date:  2006       Impact factor: 1.065

6.  Consensus development conference statement on dental sealants in the prevention of tooth decay. National Institutes of Health.

Authors: 
Journal:  J Am Dent Assoc       Date:  1984-02       Impact factor: 3.634

7.  Diagnosis of dentin involvement in occlusal caries based on visual and radiographic examination of the teeth.

Authors:  R B Nytun; M Raadal; I Espelid
Journal:  Scand J Dent Res       Date:  1992-06

8.  Effect of placing a clear sealant on the validity and reproducibility of occlusal caries detection by a laser fluorescence device: an in vitro study.

Authors:  C Deery; J Iloya; Z J Nugent; V Srinivasan
Journal:  Caries Res       Date:  2006       Impact factor: 4.056

9.  A follow-up study of the use of DIAGNOdent for monitoring fissure caries in children.

Authors:  V Anttonen; L Seppä; H Hausen
Journal:  Community Dent Oral Epidemiol       Date:  2004-08       Impact factor: 3.383

10.  Assessment of the accuracy of visual examination, bite-wing radiographs and DIAGNOdent on the diagnosis of occlusal caries.

Authors:  A M Costa; A C B Bezzerra; A B Fuks
Journal:  Eur Arch Paediatr Dent       Date:  2007-06
View more
  4 in total

1.  Assessment of early occlusal caries pre- and post-sealant application--an imaging approach.

Authors:  Jennifer S Holtzman; Jami Ballantine; Margherita Fontana; Alex Wang; Alden Calantog; Erika Benavides; Carlos Gonzalez-Cabezas; Zhongping Chen; Petra Wilder-Smith
Journal:  Lasers Surg Med       Date:  2014-04-11       Impact factor: 4.025

2.  Fluorescence devices for the detection of dental caries.

Authors:  Richard Macey; Tanya Walsh; Philip Riley; Anne-Marie Glenny; Helen V Worthington; Patrick A Fee; Janet E Clarkson; David Ricketts
Journal:  Cochrane Database Syst Rev       Date:  2020-12-08

3.  Visual or visual-tactile examination to detect and inform the diagnosis of enamel caries.

Authors:  Richard Macey; Tanya Walsh; Philip Riley; Anne-Marie Glenny; Helen V Worthington; Lucy O'Malley; Janet E Clarkson; David Ricketts
Journal:  Cochrane Database Syst Rev       Date:  2021-06-14

4.  The effects of opaque and clear pit and fissure sealants on infrared laser fluorescence measurements.

Authors:  Z Bahrololoomi; M Khodabakhsh; Y Khaksar
Journal:  J Dent (Shiraz)       Date:  2014-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.