| Literature DB >> 20098567 |
Jain Reji George1, Raksha Kushwah, K V S Sastry.
Abstract
Board of Radiation and Isotope Technology, a unit of the Department of Atomic Energy, fabricates and supplies radioactive sources for medical, industrial, agriculture and research applications. High specific activity cobalt-60, required for teletherapy is normally imported. There was a proposal for manufacturing high specific activity sources indigenously. A study was carried out to observe the feasibility of mixing imported and indigenous cobalt-60 pellets to fabricate teletherapy source capsules. The specific activity of imported pellets is more than 300 Ci/g, whereas that of indigenous pellets obtained from Indian power reactors is 140 Ci/g. The radiation output from a capsule for different combinations of specific activity was evaluated. Losses due to self-absorption were accounted in the evaluations. In another study, the optimized lengths of the capsule for an output of 200 RMM and the additional activity to be added to compensate losses due to self-absorption were also estimated for different specific activity pellets. Sources fabricated on the basis of this study showed a good agreement with the estimations. Source capsules with a combination of different specific activities are yet to be fabricated.Entities:
Keywords: 60Co pellets; Content activity and specific activity; radiation output (RMM); teletherapy
Year: 2009 PMID: 20098567 PMCID: PMC2807685 DOI: 10.4103/0971-6203.54854
Source DB: PubMed Journal: J Med Phys ISSN: 0971-6203
Figure 1Telecobalt source capsule
Radiation output from source capsule
| 1. | Only 320 Ci/g | 14400 | 250.3 |
| 2. | Only 140 Ci/g | 6300 | 109.5 |
| 3. | 320 and 140 Ci/g-uniformly combined | 10350 | 179.9 |
| 4. | 320 Ci/g up and | 7200 | 178.2 |
| 140 Ci/g down (1:1) | 3150 | ||
| 5. | 140 Ci/g up and | 3150 | 196.8 |
| 320 Ci/g down (1:1) | 7200 | ||
| 6. | 140 Ci/g up and | 4200 | 170.9 |
| 320 Ci/g down (2:1) | 4800 | ||
| 7. | 320 Ci/g up and | 4800 | 152 |
| 140 Ci/g down (1:2) | 4200 | ||
Optimization of source capsule length
| 250 | 11455 | 26.0% | 21.4 |
| 270 | 11318 | 24.5% | 19.8 |
| 300 | 11036 | 21.4% | 17.8 |
| Internal diameter of source capsule: | 20 mm |
| Length of source capsule: | 29 mm |
| Size of 60Co pellets: | 1 mm × 1 mm |
| Specific activity of imported pellets: | 320 Ci/g |
| Specific activity of indigenous pellets: | 140 Ci/g |
| Packing density of pellets in the capsule: | 5.4 g/cc |