Comparison of various parameters for radiation sources of photon beams
| 1 | Build up | Equivalent to 4MV Build-up 5 mm | Emean ∼ 2 MeV Build up 15 mm | Emean ∼ 6 MeV Build up 28-35 mm |
| 2 | Skin dose | 40-50% | ∼ 25% | ∼ 15-25% |
| 3 | Penumbra | 90-10% is 1.5 cm Field definition 50% | Sharp beam field definition 80% | Sharp beam field definition 80% |
| 4 | Penetration | 54% (10 cm) | 67% (10 cm) | 77% (10 cm) |
| 5 | Source distance | 80 cm | 100 cm | 100 cm |
| 6 | Shape of isodose curves | Rounded beyond central zone (correctable)[ | Flattened with special filter | Flattened with special filter |
| 7 | Side scatter | Less | Less | Less |
| 8 | Integral dose/tumor dose ratio | More for non-optimal plans. Manageable with good plans. | Less with simple fields | Less with simple fields |
| 9 | Absorption in bone | No differential absorption | No differential absorption | No differential absorption |
| 10 | Beam collimation | Asymmetric collimator (Yes) | Asymmetric collimators | Assymetric collimators |
| MLC being tried | MLC, IMRT, SRT | MLC, IMRT | ||
| 11 | Irregular fields | Achievable with blocks. MLC being tried[ | MLC, mMLC | MLC |
| 12 | Patients Registration | Possible | Networking yes | Networking yes |
| 13 | Computerized control console | Yes | Yes | Yes |
| 14 | Clinical acceptability | Yes (WHO,[ | Yes | Yes |
| Van Dyk,[ | ||||
| 15 | Provision of performing tomotherapy | Feasibility reported'[ | Dedicated machine | ---- |