Literature DB >> 20097606

A new EEG recording system for passive dry electrodes.

Gaetano Gargiulo1, Rafael A Calvo, Paolo Bifulco, Mario Cesarelli, Craig Jin, Armin Mohamed, André van Schaik.   

Abstract

OBJECTIVE: We present a new, low power EEG recording system with an ultra-high input impedance that enables the use of long-lasting, passive dry electrodes. It incorporates Bluetooth wireless connectivity and is designed to be suitable for long-term monitoring during daily activities.
METHODS: The new EEG system is compared to a standard and clinically available reference EEG system using wet electrodes in three separate sets of experiments. In the first two experiments, each dry electrode was surrounded by four standard wet electrodes and the alpha and mu-rhythms were recorded. In the third experiment, serial monopolar (referred to the left ear) recordings of flash visual evoked potential were performed using the new EEG system and a reference system.
RESULTS: These experiments showed that the signal recorded using the new EEG system is almost identical to that recorded with standard clinical EEG equipment; our measurements showed that the correlation coefficient between the dry electrode recordings and the average of the four standard electrodes surrounding each dry electrode is greater than 0.85.
CONCLUSION: We conclude that the new EEG system performs similarly to reference EEG systems, while providing the advantages of portability, ease of application and minimal scalp preparation. SIGNIFICANCE: The proposed system using passive dry electrodes suitable for single use while performing as good as standard EEG equipment provides ease of application and minimal scalp preparation. Copyright 2009 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

Mesh:

Year:  2010        PMID: 20097606     DOI: 10.1016/j.clinph.2009.12.025

Source DB:  PubMed          Journal:  Clin Neurophysiol        ISSN: 1388-2457            Impact factor:   3.708


  23 in total

Review 1.  Brain computer interfaces, a review.

Authors:  Luis Fernando Nicolas-Alonso; Jaime Gomez-Gil
Journal:  Sensors (Basel)       Date:  2012-01-31       Impact factor: 3.576

2.  An optimized design of seizure detection system using joint feature extraction of multichannel EEG signals.

Authors:  Dattaprasad Torse; Veena Desai; Rajashri Khanai
Journal:  J Biomed Res       Date:  2019-10-17

Review 3.  Dry EEG electrodes.

Authors:  M A Lopez-Gordo; D Sanchez-Morillo; F Pelayo Valle
Journal:  Sensors (Basel)       Date:  2014-07-18       Impact factor: 3.576

4.  Design, Fabrication, and Experimental Validation of Novel Flexible Silicon-Based Dry Sensors for Electroencephalography Signal Measurements.

Authors:  Yi-Hsin Yu; Shao-Wei Lu; Lun-De Liao; Chin-Teng Lin
Journal:  IEEE J Transl Eng Health Med       Date:  2014-11-06       Impact factor: 3.316

5.  Review of the BCI Competition IV.

Authors:  Michael Tangermann; Klaus-Robert Müller; Ad Aertsen; Niels Birbaumer; Christoph Braun; Clemens Brunner; Robert Leeb; Carsten Mehring; Kai J Miller; Gernot R Müller-Putz; Guido Nolte; Gert Pfurtscheller; Hubert Preissl; Gerwin Schalk; Alois Schlögl; Carmen Vidaurre; Stephan Waldert; Benjamin Blankertz
Journal:  Front Neurosci       Date:  2012-07-13       Impact factor: 4.677

6.  The Berlin Brain-Computer Interface: Non-Medical Uses of BCI Technology.

Authors:  Benjamin Blankertz; Michael Tangermann; Carmen Vidaurre; Siamac Fazli; Claudia Sannelli; Stefan Haufe; Cecilia Maeder; Lenny Ramsey; Irene Sturm; Gabriel Curio; Klaus-Robert Müller
Journal:  Front Neurosci       Date:  2010-12-08       Impact factor: 4.677

7.  Investigating the role of combined acoustic-visual feedback in one-dimensional synchronous brain computer interfaces, a preliminary study.

Authors:  Gaetano D Gargiulo; Armin Mohamed; Alistair L McEwan; Paolo Bifulco; Mario Cesarelli; Craig T Jin; Mariano Ruffo; Jonathan Tapson; André van Schaik
Journal:  Med Devices (Auckl)       Date:  2012-09-26

8.  A low-power bio-potential acquisition system with flexible PDMS dry electrodes for portable ubiquitous healthcare applications.

Authors:  Chih-Yuan Chen; Chia-Lin Chang; Chih-Wei Chang; Shin-Chi Lai; Tsung-Fu Chien; Hong-Yi Huang; Jin-Chern Chiou; Ching-Hsing Luo
Journal:  Sensors (Basel)       Date:  2013-03-04       Impact factor: 3.576

9.  Independent home use of a brain-computer interface by people with amyotrophic lateral sclerosis.

Authors:  Jonathan R Wolpaw; Richard S Bedlack; Domenic J Reda; Robert J Ringer; Patricia G Banks; Theresa M Vaughan; Susan M Heckman; Lynn M McCane; Charles S Carmack; Stefan Winden; Dennis J McFarland; Eric W Sellers; Hairong Shi; Tamara Paine; Donald S Higgins; Albert C Lo; Huned S Patwa; Katherine J Hill; Grant D Huang; Robert L Ruff
Journal:  Neurology       Date:  2018-06-27       Impact factor: 11.800

10.  Design and assessment of a low-cost, electromyographically controlled, prosthetic hand.

Authors:  Massimo Polisiero; Paolo Bifulco; Annalisa Liccardo; Mario Cesarelli; Maria Romano; Gaetano D Gargiulo; Alistair L McEwan; Massimo D'Apuzzo
Journal:  Med Devices (Auckl)       Date:  2013-06-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.