Literature DB >> 20097062

Conformal locoregional breast irradiation with an oblique parasternal photon field technique.

Katrien Erven1, Saskia Petillion, Caroline Weltens, Frank Van den Heuvel, Gilles Defraene, Erik Van Limbergen, Walter Van den Bogaert.   

Abstract

We evaluated an isocentric technique for conformal irradiation of the breast, internal mammary, and medial supra-clavicular lymph nodes (IM-MS LN) using the oblique parasternal photon (OPP) technique. For 20 breast cancer patients, the OPP technique was compared with a conventional mixed-beam technique (2D) and a conformal partly wide tangential (PWT) technique, using dose-volume histogram analysis and normal tissue complication probabilities (NTCPs). The 3D techniques resulted in a better target coverage and homogeneity than did the 2D technique. The homogeneity index for the IM-MS PTV increased from 0.57 for 2D to 0.90 for PWT and 0.91 for OPP (both p < 0.001). The OPP technique was able to reduce the volume of heart receiving more than 30 Gy (V(30)), the cardiac NTCP, and the volume of contralateral breast receiving 5 Gy (V(5)) compared with the PWT plans (all p < 0.05). There is no significant difference in mean lung dose or lung NTCP between both 3D techniques. Compared with the PWT technique, the volume of lung receiving more than 20 Gy (V(20)) was increased with the OPP technique, whereas the volume of lung receiving more than 40 Gy (V(40)) was decreased (both p < 0.05). Compared with the PWT technique, the OPP technique can reduce doses to the contralateral breast and heart at the expense of an increased lung V(20).
Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20097062     DOI: 10.1016/j.meddos.2009.10.006

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  4 in total

Review 1.  Treatment techniques to reduce cardiac irradiation for breast cancer patients treated with breast-conserving surgery and radiation therapy: a review.

Authors:  Robert E Beck; Leonard Kim; Ning J Yue; Bruce G Haffty; Atif J Khan; Sharad Goyal
Journal:  Front Oncol       Date:  2014-11-14       Impact factor: 6.244

2.  Efficacy and workload analysis of a fixed vertical couch position technique and a fixed-action-level protocol in whole-breast radiotherapy.

Authors:  Saskia Petillion; Karolien Verhoeven; Caroline Weltens; Frank Van den Heuvel
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

3.  A cardiac contouring atlas for radiotherapy.

Authors:  Frances Duane; Marianne C Aznar; Freddie Bartlett; David J Cutter; Sarah C Darby; Reshma Jagsi; Ebbe L Lorenzen; Orla McArdle; Paul McGale; Saul Myerson; Kazem Rahimi; Sindu Vivekanandan; Samantha Warren; Carolyn W Taylor
Journal:  Radiother Oncol       Date:  2017-02-21       Impact factor: 6.280

4.  Accuracy of a new paired imaging technique for position correction in whole breast radiotherapy.

Authors:  Saskia Petillion; Karolien Verhoeven; Caroline Weltens; Frank Van den Heuvel
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.