Literature DB >> 20097060

Conkiss: conformal kidneys sparing 3D noncoplanar radiotherapy treatment for pancreatic cancer as an alternative to IMRT.

Zsolt Sebestyén1, Péter Kovács, Ákos Gulybán, Róbert Farkas, Szabolcs Bellyei, Gábor Liposits, András Szigeti, Olga Esik, Katalin Dérczy, László Mangel.   

Abstract

When treating pancreatic cancer using standard (ST) 3D conformal radiotherapy (3D-CRT) beam arrangements, the kidneys often receive a higher dose than their probable tolerance limit. Our aim was to elaborate a new planning method that--similarly to IMRT--effectively spares the kidneys without compromising the target coverage. Conformal kidneys sparing (CONKISS) 5-field, noncoplanar plans were compared with ST plans for 23 consecutive patients retrospectively. Optimal beam arrangements were used consisting of a left- and right-wedged beam-pair and an anteroposterior beam inclined in the caudal direction. The wedge direction determination (WEDDE) algorithm was developed to adjust the adequate direction of wedges. The aimed organs at risk (OARs) mean dose limits were: kidney <12 Gy, liver <25 Gy, small bowels <30 Gy, and spinal cord maximum <45 Gy. Conformity and homogeneity indexes with z-test were used to evaluate and compare the different planning approaches. The mean dose to the kidneys decreased significantly (p < 0.05): left kidney 7.7 vs. 10.7 Gy, right kidney 9.1 vs. 11.7 Gy. Meanwhile the mean dose to the liver increased significantly (18.1 vs. 15.0 Gy). The changes in the conformity, homogeneity, and in the doses to other OARs were not significant. The CONKISS method balances the load among the OARs and significantly reduces the dose to the kidneys, without any significant change in the conformity and homogeneity. Using 3D-CRT the CONKISS method can be a smart alternative to IMRT to enhance the possibility of dose escalation.
Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20097060     DOI: 10.1016/j.meddos.2009.11.001

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  2 in total

1.  Beam angle selection for intensity-modulated radiotherapy (IMRT) treatment of unresectable pancreatic cancer: are noncoplanar beam angles necessary?

Authors:  D S Chang; G K Bartlett; I J Das; H R Cardenes
Journal:  Clin Transl Oncol       Date:  2013-01-29       Impact factor: 3.405

2.  Free-breathing conformal irradiation of pancreatic cancer.

Authors:  Ignazio Solla; Sergio Zucca; Marco Possanzini; Sara Piras; Claudio Pusceddu; Sergio Porru; Gianfranco Meleddu; Paolo Farace
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.