Analysis of high-frequency rotational angioplasty-induced echo contrast.

R Zotz1, P Stähr, R Erbel, D Auth, J Meyer.   

Abstract

During high-frequency rotational angioplasty (HFRA), myocardial contrast enhancement (echo contrast) was observed by means of two-dimensional echocardiography. In order to evaluate the echo contrast produced by HFRA, an in vitro experimental model was built using a cylinder with the HFRA catheter scanned in a water bath. The cylinder was filled with blood, mineral water, and distilled water. With a 2.5-MHz transducer, echograms were recorded and analyzed by video intensitometer, and the maximum intensity IUmax and persistence time P were calculated. Rotation frequencies of 20,000-200,000 rpm with 2.0--mm burrs and times of 10 s were tested. In another model, hyperbaric conditions for the same media were produced. The influence of debris from arterioscleroic plaque and of hematocrit on echo contrast intensity were also analyzed. The effect of HFRA on hemolysis (LDH, free hemoglobin) within 10 s and temperature were also measured. The contrast effect was transient, depending on the rotation frequency. In blood, it appeared at 20,000 rpm (IUmax at 200,000 rpm: 237 IU), in mineral water at 40,000 rpm (IUmax 165 IU), and in distilled water at 80,000 rpm (IUmax 72 IU). Persistence time was measured up to about a half-minute. Echo contrast production was reduced at 0.5 bar and fully suppressed at 2.5 bar. Debris increased contrast intensity from about 219 IU to 225 IU (at 160,000 rpm). In blood IUmax decreased from 227 IU to 97 IU by lowering the hematocrit from 44.2% to 3.6%.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 2009564     DOI: 10.1002/ccd.1810220215

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  5 in total

Review 1.  Characterization of the rdar morphotype, a multicellular behaviour in Enterobacteriaceae.

Authors:  U Römling
Journal:  Cell Mol Life Sci       Date:  2005-06       Impact factor: 9.261

2.  [Echocardiography : Important diagnostic pillar in cardiology].

Authors:  R Erbel
Journal:  Herz       Date:  2017-05       Impact factor: 1.443

3.  High frequency rotational ablation: an alternative in treating coronary artery stenoses and occlusions.

Authors:  U Dietz; R Erbel; H J Rupprecht; S Weidmann; J Meyer
Journal:  Br Heart J       Date:  1993-10

4.  Rotational ablation of discrete lesions in the coronary arteries is safe. A nonrandomized comparison with percutaneous transluminal coronary angioplasty.

Authors:  J Cheirif; R Wray; J Heibig; S Harris; R Staudacher; M Bucay; N Zacca
Journal:  Tex Heart Inst J       Date:  1995

Review 5.  Rotational Atherectomy: A Contemporary Appraisal.

Authors:  Tanush Gupta; Michael Weinreich; Mark Greenberg; Antonio Colombo; Azeem Latib
Journal:  Interv Cardiol       Date:  2019-11-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.