Literature DB >> 20093516

In vivo MR angiography and velocity measurement in mice coronary arteries at 9.4 T: assessment of coronary flow velocity reserve.

Hubert Cochet1, Michel Montaudon, François Laurent, Guillaume Calmettes, Jean-Michel Franconi, Sylvain Miraux, Eric Thiaudière, Elodie Parzy.   

Abstract

PURPOSE: To demonstrate the feasibility of coronary magnetic resonance (MR) angiography in living mice and to evaluate a dynamic MR angiographic method for coronary flow measurement at 9.4-T field strength.
MATERIALS AND METHODS: This study was conducted according to European law and was in full compliance with National Institutes of Health recommendations for animal care and a local institutional animal care committee. Mice were anesthetized by using isoflurane. First, time-of-flight MR angiography was performed in 10 mice to measure coronary diameters at 80-mum isotropic resolution. Second, left coronary artery (LCA) velocity measurements were performed at seven cardiac phases in nine other mice to assess the velocity curve profile. Third, coronary velocities were measured at the middiastolic phase in 13 mice at rest and during adenosine-induced hyperemia to calculate coronary flow velocity reserve (CFVR). The Pearson coefficient compared the correlation between isoflurane dose and CFVR. Paired t tests compared R-R intervals and respiratory rates between rest and hyperemia.
RESULTS: Proximal diameters were, respectively, 404 mum +/- 34 [standard deviation] and 259 mum +/- 22 for the LCAs and the right coronary arteries, which were in accordance with reported values. The velocity curve profile throughout the cardiac cycle was similar to values from the literature. Baseline and hyperemic velocities were, respectively, 19.0 cm/sec +/- 4.4 and 33.7 cm/sec +/- 4.7 (P<.001), resulting in a CFVR of 1.77 +/- 0.19. CFVR did not correlate with isoflurane dose (r = 0.05, P = .88). R-R intervals shortened by 2.5% during hyperemia (P = .04). Respiratory rates showed no difference between rest and hyperemia (P = .39).
CONCLUSION: High-spatial-resolution three-dimensional coronary MR angiography is feasible in living mice. Dynamic MR angiography depicts coronary velocity changes throughout the cardiac cycle and between rest and maximum hyperemia, providing a tool for CFVR assessment. (c) RSNA, 2010

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20093516     DOI: 10.1148/radiol.2542090735

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Retrograde perfusion and filling of mouse coronary vasculature as preparation for micro computed tomography imaging.

Authors:  Jill J Weyers; Dara D Carlson; Charles E Murry; Stephen M Schwartz; William M Mahoney
Journal:  J Vis Exp       Date:  2012-02-10       Impact factor: 1.355

2.  Comprehensive phenotyping of salt-induced hypertensive heart disease in living mice using cardiac magnetic resonance.

Authors:  Hubert Cochet; William Lefrançois; Michel Montaudon; François Laurent; Line Pourtau; Sylvain Miraux; Elodie Parzy; Jean-Michel Franconi; Eric Thiaudière
Journal:  Eur Radiol       Date:  2012-07-27       Impact factor: 5.315

3.  Molecular Mechanisms of Adenosine Stress T1 Mapping.

Authors:  Soham A Shah; Claire E Reagan; Brent A French; Frederick H Epstein
Journal:  Circ Cardiovasc Imaging       Date:  2021-03-12       Impact factor: 7.792

4.  Positive contrast high-resolution 3D-cine imaging of the cardiovascular system in small animals using a UTE sequence and iron nanoparticles at 4.7, 7 and 9.4 T.

Authors:  Aurélien J Trotier; William Lefrançois; Kris Van Renterghem; Jean-Michel Franconi; Eric Thiaudière; Sylvain Miraux
Journal:  J Cardiovasc Magn Reson       Date:  2015-07-07       Impact factor: 5.364

5.  Coronary micro-computed tomography angiography in mice.

Authors:  Stefan Sawall; Jan Beckendorf; Carlo Amato; Joscha Maier; Johannes Backs; Greetje Vande Velde; Marc Kachelrieß; Jan Kuntz
Journal:  Sci Rep       Date:  2020-10-08       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.