Literature DB >> 20093244

Collection of blood specimens by venipuncture for plasma-based coagulation assays: necessity of a discard tube.

Maarten T M Raijmakers1, Carolien H F Menting, Huib L Vader, Fedde van der Graaf.   

Abstract

The Clinical and Laboratory Standards Institute (CLSI) recently abandoned its recommendation for drawing a discard tube when performing a prothrombin time (PT)/international normalized ratio (INR) or an activated partial thromboplastin time (APTT). Because there is currently no evidence that a discard tube is necessary for more specialized coagulation assays, we studied the need for a discard tube for some of these tests. Blood was obtained from 88 subjects in 2 subsequent citrate tubes. Platelet-free plasma was tested for PT, APTT, antithrombin, protein C, and factors II, V, VIII, IX, and X. Difference and bias between tubes were tested using the Wilcoxon signed rank test and Bland-Altman plots. For only APTT, antithrombin, and protein C was a small, statistically significant mean bias found (0.5 seconds; P = .001; -0.7%, P = .002; and -0.8%, P < .0001, respectively), but the bias of individual samples was not clinically relevant. This was also true for the other parameters tested. The recent CLSI recommendation that a discard tube is not necessary for PT/INR and APTT can be extended to include more specialized plasma-based coagulation assays as identified in this study.

Entities:  

Mesh:

Year:  2010        PMID: 20093244     DOI: 10.1309/AJCP9ATB0AXPFJCC

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  6 in total

1.  Routine coagulation testing: do we need a discard tube?

Authors:  Markas Masih; Naveen Kakkar
Journal:  Indian J Hematol Blood Transfus       Date:  2013-07-09       Impact factor: 0.900

Review 2.  Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories.

Authors:  A Magnette; M Chatelain; B Chatelain; H Ten Cate; F Mullier
Journal:  Thromb J       Date:  2016-12-12

Review 3.  Preanalytical investigations of phlebotomy: methodological aspects, pitfalls and recommendations.

Authors:  Cristiano Ialongo; Sergio Bernardini
Journal:  Biochem Med (Zagreb)       Date:  2017-02-15       Impact factor: 2.313

4.  Vacuum-venipuncture skills: time required and importance of tube order.

Authors:  Chieko Fujii
Journal:  Vasc Health Risk Manag       Date:  2013-08-05

Review 5.  Croatian Society of Medical Biochemistry and Laboratory Medicine: national recommendations for venous blood sampling.

Authors:  Nora Nikolac; Vesna Supak-Smolcić; Ana-Maria Simundić; Ivana Celap
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

6.  Comparison of clot-based and chromogenic assay for the determination of protein c activity.

Authors:  Tariq M Roshan; Nancy Stein; Xiu Y Jiang
Journal:  Blood Coagul Fibrinolysis       Date:  2019-06       Impact factor: 1.276

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.