Literature DB >> 20092093

Investigation of relative micromotion at the stem-cement interface in total hip replacement.

H Y Zhang1, L Brown, S Barrans, L Blunt, X Q Jiang.   

Abstract

Cemented total hip replacement has become a standard surgical technique to treat patients with osteoarthritis and osteonecrosis. The stem-cement interface experiences fretting wear in vivo due to low-amplitude oscillatory micromotion under physiological loading, and this wear is currently becoming important as a potential mechanism for the overall wear of cemented total hip replacements. However, the relative micromotion at the stem-cement interface has not been widely reported. In the present study, a new micromotion sensor is developed that is based on the deformation of a strain gauge, and this sensor is used to probe the migration of a polished Exeter stem within a Simplex P cement mantle through an in vitro wear simulation. It is demonstrated that the stem migration value generally increases with an increase in the number of loading cycles, with a gradual decrease of migration rate. Additionally, fretting wear is successfully replicated on the stem surface, and the micropores in the cement surface are considered to contribute to initiation and propagation of the fretting damage on the stem. This is confirmed by the observation that no evidence of fretting wear is detected on the stem where the surface is in contact with the pore-free areas on the cement. This study allows a deep insight into the micromotion at the stem-cement interface, and provides evidence highlighting the significance of the micropores in the cement surface in the generation of fretting wear on a polished femoral stem.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20092093     DOI: 10.1243/09544119JEIM594

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  2 in total

1.  Increased receptor activator of nuclear factor κβ ligand/osteoprotegerin ratio exacerbates cartilage destruction in osteoarthritis in vitro.

Authors:  Ji-Zhou Zeng; Zhen-Zhong Wang; Li-Feng Ma; Hai Meng; Hao-Miao Yu; Wen-Hao Cheng; Ya-Kui Zhang; Ai Guo
Journal:  Exp Ther Med       Date:  2016-08-31       Impact factor: 2.447

2.  Influence of Ceramic Debris on Osteoblast Behaviors: An In Vivo Study.

Authors:  Guo-Jing Sun; Shu-Feng Yang; Yun-Fan Ti; Guo-Dong Guo; Geng-Tao Fan; Feng-Rong Chen; Shao-Gang Xu; Jian-Ning Zhao
Journal:  Orthop Surg       Date:  2019-08-28       Impact factor: 2.071

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.