Literature DB >> 20091104

Microscale wear behavior and crosslinking of PEG-like coatings for total hip replacements.

Sheryl R Kane1, Paul D Ashby, Lisa A Pruitt.   

Abstract

The predominant cause of late-state failure of total hip replacements is wear-mediated osteolysis caused by wear particles that originate from the ultrahigh molecular weight polyethylene (UHMWPE) acetabular cup surface. One strategy for reducing wear particle formation from UHMWPE is to modify the surface with a hydrophilic coating to increase lubrication from synovial fluid. This study focuses on the wear behavior of hydrophilic coatings similar to poly(ethylene glycol) (PEG). The coatings were produced by plasma-polymerizing tetraglyme on UHMWPE in a chamber heated to 40 degrees C or 50 degrees C. Both temperatures yielded coatings with PEG-like chemistry and increased hydrophilicity relative to uncoated UHMWPE; however, the 40 degrees C coatings were significantly more resistant to damage induced by atomic force microscopy nanoscratching. The 40 degrees C coatings exhibited only one damage mode (delamination) and often showed no signs of damage after repeated scratching. In contrast, the 50 degrees C coatings exhibited three damage modes (roughening, thinning, and delamination), and always showed visible signs of damage after no more than two scratches. The greater wear resistance of the 40 degrees C coatings could not be explained by coating chemistry or hydrophilicity, but it corresponded to an approximately 26-32% greater degree of crosslinking relative to the 50 degrees C surfaces, suggesting that crosslinking should be a significant design consideration for hydrophilic coatings used for total hip replacements and other wear-dependent applications.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20091104      PMCID: PMC2848970          DOI: 10.1007/s10856-009-3935-6

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  14 in total

1.  Comparison of cross-linked polyethylene materials for orthopaedic applications.

Authors:  John P Collier; Barbara H Currier; Francis E Kennedy; John H Currier; Graham S Timmins; Simon K Jackson; Robin L Brewer
Journal:  Clin Orthop Relat Res       Date:  2003-09       Impact factor: 4.176

Review 2.  Particle bioreactivity and wear-mediated osteolysis.

Authors:  Mark L Wang; Peter F Sharkey; Rocky S Tuan
Journal:  J Arthroplasty       Date:  2004-12       Impact factor: 4.757

3.  Wear reduction of orthopaedic bearing surfaces using polyelectrolyte multilayer nanocoatings.

Authors:  Prem V Pavoor; Brian P Gearing; Orhun Muratoglu; Robert E Cohen; Anuj Bellare
Journal:  Biomaterials       Date:  2005-09-19       Impact factor: 12.479

4.  The origin of submicron polyethylene wear debris in total hip arthroplasty.

Authors:  H A McKellop; P Campbell; S H Park; T P Schmalzried; P Grigoris; H C Amstutz; A Sarmiento
Journal:  Clin Orthop Relat Res       Date:  1995-02       Impact factor: 4.176

5.  Plasma deposition and surface characterization of oligoglyme, dioxane, and crown ether nonfouling films.

Authors:  Erika E Johnston; James D Bryers; Buddy D Ratner
Journal:  Langmuir       Date:  2005-02-01       Impact factor: 3.882

6.  Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis.

Authors:  Toru Moro; Yoshio Takatori; Kazuhiko Ishihara; Tomohiro Konno; Yorinobu Takigawa; Tomiharu Matsushita; Ung-Il Chung; Kozo Nakamura; Hiroshi Kawaguchi
Journal:  Nat Mater       Date:  2004-10-24       Impact factor: 43.841

7.  A novel ultra high molecular weight polyethylene-hyaluronan microcomposite for use in total joint replacements. II. Mechanical and tribological property evaluation.

Authors:  Min Zhang; Philippe Pare; Richard King; Susan P James
Journal:  J Biomed Mater Res A       Date:  2007-07       Impact factor: 4.396

8.  The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene.

Authors:  D A Baker; A Bellare; L Pruitt
Journal:  J Biomed Mater Res A       Date:  2003-07-01       Impact factor: 4.396

9.  Characterization and tribology of PEG-like coatings on UHMWPE for total hip replacements.

Authors:  Sheryl R Kane; Paul D Ashby; Lisa A Pruitt
Journal:  J Biomed Mater Res A       Date:  2010-03-15       Impact factor: 4.396

10.  ATR-FTIR as a thickness measurement technique for hydrated polymer-on-polymer coatings.

Authors:  Sheryl R Kane; Paul D Ashby; Lisa A Pruitt
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-11       Impact factor: 3.368

View more
  1 in total

1.  Implantation and Extraction of Penetrating Electrode Arrays in Minipig Retinas.

Authors:  Jinghua Chen; Vasiliki Poulaki; Seong-Joon Kim; William D Eldred; Sheryl Kane; Marcus Gingerich; Douglas B Shire; Ralph Jensen; Gloria DeWalt; Henry J Kaplan; Joseph F Rizzo
Journal:  Transl Vis Sci Technol       Date:  2020-04-24       Impact factor: 3.283

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.