Literature DB >> 20089819

Reliability and frequency response of excitatory signals transmitted to different types of retinal ganglion cell.

Michael A Freed1, Zhiyin Liang.   

Abstract

The same visual stimulus evokes a different pattern of neural signals each time the stimulus is presented. Because this unreliability reduces visual performance, it is important to understand how it arises from neural circuitry. We asked whether different types of ganglion cell receive excitatory signals with different reliability and frequency content and, if so, how retinal circuitry contributes to these differences. If transmitter release is governed by Poisson statistics, the SNR of the postsynaptic currents (ratio of signal power to noise power) should grow linearly with quantal rate (qr), a prediction that we confirmed experimentally. Yet ganglion cells of the same type receive quanta at different rates. Thus to obtain a measure of reliability independent of quantal rate, we calculated the ratio SNR/qr, and found this measure to be type-specific. We also found type-specific differences in the frequency content of postsynaptic currents, although types whose dendrites branched at nearby levels of the inner plexiform layer (IPL) had similar frequency content. As a result, there was an orderly distribution of frequency response through the depth of the IPL, with alternating layers of broadband and high-pass signals. Different types of bipolar cell end at different depths of the IPL and provide excitatory synapses to ganglion cell dendrites there. Thus these findings indicate that a bipolar cell synapse conveys signals whose temporal message and reliability (SNR/qr) are determined by neuronal type. The final SNR of postsynaptic currents is set by the dendritic membrane area of a ganglion cell, which sets the numbers of bipolar cell synapses and thus the rate at which it receives quanta [SNR = qr x (SNR/qr)].

Mesh:

Year:  2010        PMID: 20089819      PMCID: PMC2887626          DOI: 10.1152/jn.00871.2009

Source DB:  PubMed          Journal:  J Neurophysiol        ISSN: 0022-3077            Impact factor:   2.714


  32 in total

1.  The performance of synapses that convey discrete graded potentials in an insect visual pathway.

Authors:  P J Simmons
Journal:  J Neurosci       Date:  1999-12-01       Impact factor: 6.167

2.  Vertical interactions across ten parallel, stacked representations in the mammalian retina.

Authors:  B Roska; F Werblin
Journal:  Nature       Date:  2001-03-29       Impact factor: 49.962

3.  Transmitter release at the hair cell ribbon synapse.

Authors:  Elisabeth Glowatzki; Paul A Fuchs
Journal:  Nat Neurosci       Date:  2002-02       Impact factor: 24.884

4.  Exocytosed protons feedback to suppress the Ca2+ current in mammalian cone photoreceptors.

Authors:  S H DeVries
Journal:  Neuron       Date:  2001-12-20       Impact factor: 17.173

5.  The diversity of ganglion cells in a mammalian retina.

Authors:  Rebecca L Rockhill; Frank J Daly; Margaret A MacNeil; Solange P Brown; Richard H Masland
Journal:  J Neurosci       Date:  2002-05-01       Impact factor: 6.167

6.  Bipolar cells use kainate and AMPA receptors to filter visual information into separate channels.

Authors:  S H DeVries
Journal:  Neuron       Date:  2000-12       Impact factor: 17.173

7.  Timing of quantal release from the retinal bipolar terminal is regulated by a feedback circuit.

Authors:  Michael A Freed; Robert G Smith; Peter Sterling
Journal:  Neuron       Date:  2003-04-10       Impact factor: 17.173

8.  Coordinated multivesicular release at a mammalian ribbon synapse.

Authors:  Joshua H Singer; Luisa Lassová; Noga Vardi; Jeffrey S Diamond
Journal:  Nat Neurosci       Date:  2004-07-04       Impact factor: 24.884

9.  Origin of transient and sustained responses in ganglion cells of the retina.

Authors:  G B Awatramani; M M Slaughter
Journal:  J Neurosci       Date:  2000-09-15       Impact factor: 6.167

10.  Loss of sensitivity in an analog neural circuit.

Authors:  Bart G Borghuis; Peter Sterling; Robert G Smith
Journal:  J Neurosci       Date:  2009-03-11       Impact factor: 6.167

View more
  8 in total

1.  Synaptic noise is an information bottleneck in the inner retina during dynamic visual stimulation.

Authors:  Michael A Freed; Zhiyin Liang
Journal:  J Physiol       Date:  2013-12-02       Impact factor: 5.182

2.  A Mammalian Retinal Ganglion Cell Implements a Neuronal Computation That Maximizes the SNR of Its Postsynaptic Currents.

Authors:  Jan Homann; Michael A Freed
Journal:  J Neurosci       Date:  2016-12-30       Impact factor: 6.167

3.  Cross inhibition from ON to OFF pathway improves the efficiency of contrast encoding in the mammalian retina.

Authors:  Zhiyin Liang; Michael A Freed
Journal:  J Neurophysiol       Date:  2012-08-29       Impact factor: 2.714

4.  Astrocytes modulate neural network activity by Ca²+-dependent uptake of extracellular K+.

Authors:  Fushun Wang; Nathan A Smith; Qiwu Xu; Takumi Fujita; Akemichi Baba; Toshio Matsuda; Takahiro Takano; Lane Bekar; Maiken Nedergaard
Journal:  Sci Signal       Date:  2012-04-03       Impact factor: 8.192

5.  Asymmetry between ON and OFF α ganglion cells of mouse retina: integration of signal and noise from synaptic inputs.

Authors:  Michael A Freed
Journal:  J Physiol       Date:  2017-10-15       Impact factor: 5.182

6.  Convergence and Divergence of CRH Amacrine Cells in Mouse Retinal Circuitry.

Authors:  Silvia J H Park; Joseph Pottackal; Jiang-Bin Ke; Na Young Jun; Pouyan Rahmani; In-Jung Kim; Joshua H Singer; Jonathan B Demb
Journal:  J Neurosci       Date:  2018-03-23       Impact factor: 6.167

7.  Why do axons differ in caliber?

Authors:  János A Perge; Jeremy E Niven; Enrico Mugnaini; Vijay Balasubramanian; Peter Sterling
Journal:  J Neurosci       Date:  2012-01-11       Impact factor: 6.167

8.  Selective synaptic connections in the retinal pathway for night vision.

Authors:  Deborah L Beaudoin; Mania Kupershtok; Jonathan B Demb
Journal:  J Comp Neurol       Date:  2017-09-15       Impact factor: 3.215

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.