Literature DB >> 20087769

Segmentation of holter ECG waves via analysis of a discrete wavelet-derived multiple skewness-kurtosis based metric.

A Ghaffari1, M R Homaeinezhad, M Khazraee, M M Daevaeiha.   

Abstract

In this study, a simple mathematical-statistical based metric called Multiple Higher Order Moments (MHOM) is introduced enabling the electrocardiogram (ECG) detection-delineation algorithm to yield acceptable results in the cases of ambulatory holter ECG including strong noise, motion artifacts, and severe arrhythmia(s). In the MHOM measure, important geometric characteristics such as maximum value to minimum value ratio, area, extent of smoothness or being impulsive and distribution skewness degree (asymmetry), occult. In the proposed method, first three leads of high resolution 24-h holter data are extracted and preprocessed using Discrete Wavelet Transform (DWT). Next, a sample to sample sliding window is applied to preprocessed sequence and in each slid, mean value, variance, skewness, and kurtosis of the excerpted segment are superimposed called MHOM. The MHOM metric is then used as decision statistic to detect and delineate ECG events. To show advantages of the presented method, it is applied to MIT-BIH Arrhythmia Database, QT Database, and T-Wave Alternans Database and as a result, the average values of sensitivity and positive predictivity Se = 99.95% and P+ = 99.94% are obtained for the detection of QRS complexes, with the average maximum delineation error of 6.1, 4.1, and 6.5 ms for P-wave, QRS complex, and T-wave, respectively showing marginal improvement of detection-delineation performance. In the next step, the proposed method is applied to DAY hospital high resolution holter data (more than 1,500,000 beats including Bundle Branch Blocks--BBB, Premature Ventricular Complex--PVC, and Premature Atrial Complex-PAC) and average values of Se = 99.97% and P+ = 99.95% are obtained for QRS detection. In summary, marginal performance improvement of ECG events detection-delineation process, reliable robustness against strong noise, artifacts, and probable severe arrhythmia(s) of high resolution holter data can be mentioned as important merits and capabilities of the proposed algorithm.

Entities:  

Mesh:

Year:  2010        PMID: 20087769     DOI: 10.1007/s10439-010-9919-3

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  8 in total

1.  Using a Calculated Pulse Rate with an Artificial Neural Network to Detect Irregular Interbeats.

Authors:  Bih-Chyun Yeh; Wen-Piao Lin
Journal:  J Med Syst       Date:  2015-12-07       Impact factor: 4.460

2.  A unified procedure for detecting, quantifying, and validating electrocardiogram T-wave alternans.

Authors:  H Naseri; H Pourkhajeh; M R Homaeinezhad
Journal:  Med Biol Eng Comput       Date:  2013-05-22       Impact factor: 2.602

3.  Single-channel EEG sleep stage classification based on a streamlined set of statistical features in wavelet domain.

Authors:  Thiago L T da Silveira; Alice J Kozakevicius; Cesar R Rodrigues
Journal:  Med Biol Eng Comput       Date:  2016-05-19       Impact factor: 2.602

4.  VERB: VFCDM-Based Electrocardiogram Reconstruction and Beat Detection Algorithm.

Authors:  Syed Khairul Bashar; Allan J Walkey; David D McManus; Ki H Chon
Journal:  IEEE Access       Date:  2019-01-21       Impact factor: 3.367

5.  An Accurate QRS complex and P wave Detection in ECG Signals using Complete Ensemble Empirical Mode Decomposition Approach.

Authors:  Billal Hossain; Syed Khairul Bashar; Allan J Walkey; David D McManus; Ki H Chon
Journal:  IEEE Access       Date:  2019-09-06       Impact factor: 3.367

6.  A New Wavelet-Based ECG Delineator for the Evaluation of the Ventricular Innervation.

Authors:  Matteo Cesari; Jesper Mehlsen; Anne-Birgitte Mehlsen; Helge Bjarup Dissing Sorensen
Journal:  IEEE J Transl Eng Health Med       Date:  2017-07-04       Impact factor: 3.316

7.  Electrocardiogram Delineation in a Wistar Rat Experimental Model.

Authors:  Pedro David Arini; Sergio Liberczuk; Javier Gustavo Mendieta; Martín Santa María; Guillermo Claudio Bertrán
Journal:  Comput Math Methods Med       Date:  2018-02-08       Impact factor: 2.238

8.  Identification of Transient Noise to Reduce False Detections in Screening for Atrial Fibrillation.

Authors:  Hesam Halvaei; Emma Svennberg; Leif Sörnmo; Martin Stridh
Journal:  Front Physiol       Date:  2021-06-04       Impact factor: 4.566

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.