Literature DB >> 20087283

The importance of a standing position in the diagnosis of Nutcracker phenomenon by duplex sonography.

A Romera-Villegas1, R Vila-Coll, M Cairols-Castellote, R Poveda-Monge, C Masuet-Aumatell, M Grinyó-Boira.   

Abstract

AIM: To determine the clinical usefulness of Doppler ultrasonography in the diagnosis of the Nutcracker phenomenon, as an alternative to computed tomographic scans (CT).
METHODS: This study consisted of 52 patients that presented with intermittent hematuria of unknown origin between January 2006 to April 2008. Doppler ultrasonography was used to assess the left renal vein (LRV) by measuring the anteroposterior (AP) diameter and peak systolic velocity (PSV) in supine and standing positions, at the hilar and interaortomesenteric portions of the LRV. These data were compared with CT scans. The sensitivity and specificity of duplex sonography was determined using the AP diameter and PSV ratios to assess the cut-off levels. Kappa (k) statistic was also evaluated.
RESULTS: mean AP diameters of the LRV measured by Doppler sonography were 8.38 mm at the hilar and 3.17 mm under the SMA, compared to 9.3 mm (hilar) and 3.2 mm (SMA) in the supine and standing position respectively. The PSV in the supine position was 25.77 cm/s and 115.48 cm/s, respectively, compared to 25.54 cm/s and 125.96 cm/s in the standing position. The cut-off levels were 3.85 (sensitivity: 61.5%, specificity: 80.8%, k:0.42) for the supine and 4.12 (sensitivity:61.5%, specificity: 65.4%, k: 0.27) for the standing AP diameter, 2.99 (sensitivity: 92.3%, specificity: 73.1%, k: 0.65) for the supine and 3.73 (sensitivity: 96.4%, specificity: 79.2%, k: 0.76) for the standing PSV.
CONCLUSIONS: Our data show that the standing PSV ratio is the best parameter for to detecting entrapment of the LRV.

Entities:  

Mesh:

Year:  2009        PMID: 20087283

Source DB:  PubMed          Journal:  Int Angiol        ISSN: 0392-9590            Impact factor:   2.789


  2 in total

1.  Renal Doppler ultrasonography in the diagnosis of nutcracker syndrome.

Authors:  Se Jin Park; Jae Il Shin
Journal:  Eur J Pediatr       Date:  2012-11-20       Impact factor: 3.183

2.  Newly-identified symptoms of left renal vein entrapment syndrome mimicking orthostatic disturbance.

Authors:  Machiko Koshimichi; Keisuke Sugimoto; Hidehiko Yanagida; Shinsuke Fujita; Tomoki Miyazawa; Naoki Sakata; Mitsuru Okada; Tsukasa Takemura
Journal:  World J Pediatr       Date:  2012-05-10       Impact factor: 2.764