[Radiation exposure of children in pediatric radiology part 8: radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants].

K Schneider1, M C Seidenbusch.   

Abstract

PURPOSE: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram.
MATERIALS AND METHODS: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PADOS, a specific dose reconstruction algorithm was developed.
RESULTS: The entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could be reduced in the last 30 years by a factor of 5 to 8. They are far below the entrance dose values reported by other radiology departments in Europe. Nevertheless, a slight increase in the entrance doses that correlates with the introduction of a digital storage phosphor system could be observed in the last years.
CONCLUSION: Because nearly all radiosensitive body organs in early life are involved during a thoracoabdominal babygram and because of the high radiation sensitivity of newborns, thoracoabdominal babygrams should be performed in neonatology with caution. A dose value of 1.0 cGy cm(2) could serve as the actual reference dose value for the thoracoabdominal babygram of the newborn. Georg Thieme Verlag KG Stuttgart New York.

Entities:  

Mesh:

Year:  2010        PMID: 20084594     DOI: 10.1055/s-0028-1109963

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  2 in total

Review 1.  [Radiology in pediatric intensive care units].

Authors:  M Beer; C Wirth; H Neubauer; J Wirbelauer
Journal:  Med Klin Intensivmed Notfmed       Date:  2011-10-29       Impact factor: 0.840

2.  Effectiveness of a radiation reduction campaign targeting children with gastrointestinal symptoms in a pediatric emergency department.

Authors:  Hyuksool Kwon; Jae Yun Jung
Journal:  Medicine (Baltimore)       Date:  2017-01       Impact factor: 1.889

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.