Effect of dimensionality of heterogeneity corrections on the implementation of a three-dimensional electron pencil-beam algorithm.

G Starkschall1, A S Shiu, S W Bujnowski, L L Wang, D A Low, K R Hogstrom.   

Abstract

Electron beam dose distributions were calculated on a three-dimensional grid using three pencil-beam algorithms, each taking into account irregularities in field shape. The algorithms differ in that patient anatomy in either one, two, or three dimensions is used in the calculation of dose to a point. Algorithms were optimized for speed by such techniques as precalculation and storage of several quantities, reordering of pencil-beam and grid-point loops, selection of cut-off values for some calculated quantities, and invoking error function symmetries. Execution times for optimized versions of each of the algorithms as implemented on a three-dimensional treatment planning system were comparable for both the one- and two-dimensional heterogeneity correction requires an additional calculational loop over fan lines. Execution times for the three-dimensional heterogeneity correction were approximately a factor of four longer than those for the two-dimensional correction. For certain geometries, three-dimensional heterogeneity corrections were necessary to calculate dose distributions accurately, in spite of the additional cost in calculation times.

Entities:  

Mesh:

Year:  1991        PMID: 2008447     DOI: 10.1088/0031-9155/36/2/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Evaluation of a mixed beam therapy for postmastectomy breast cancer patients: Bolus electron conformal therapy combined with intensity modulated photon radiotherapy and volumetric modulated photon arc therapy.

Authors:  Rui Zhang; David Heins; Mary Sanders; Beibei Guo; Kenneth Hogstrom
Journal:  Med Phys       Date:  2018-05-27       Impact factor: 4.071

2.  Modeling and measurement of the variations of CT number distributions for mobile targets in cone-beam computed tomographic imaging.

Authors:  Imad Ali; Nesreen Alsbou; Salahuddin Ahmad
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

3.  Application of a dummy eye shield for electron treatment planning.

Authors:  Sei-Kwon Kang; Soah Park; Taejin Hwang; Kwang-Ho Cheong; Taejin Han; Haeyoung Kim; Me-Yeon Lee; Kyoung Ju Kim; Do Hoon Oh; Hoonsik Bae
Journal:  J Radiat Res       Date:  2012-08-21       Impact factor: 2.724

4.  Evaluation of lens dose from anterior electron beams: comparison of Pinnacle and Gafchromic EBT3 film.

Authors:  Marcus Sonier; Matt Wronski; Collins Yeboah
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

5.  Evaluation of MVCT images with skin collimation for electron beam treatment planning.

Authors:  Allen B Beardmore; Isaac I Rosen; Dennis A Cheek; Robert S Fields; Kenneth R Hogstrom
Journal:  J Appl Clin Med Phys       Date:  2008-06-23       Impact factor: 2.102