Impact of analysis interval on the multiple exhalation flow technique to partition exhaled nitric oxide.

James L Puckett1, Richard W E Taylor, Stanley P Galant, Steven C George.   

Abstract

Exhaled nitric oxide (eNO) is elevated in asthmatics and is a purported marker of airway inflammation. By measuring eNO at multiple flows and applying models of eNO exchange dynamics, the signal can be partitioned into its proximal airway [J' aw NO (nl/sec)] and distal airway/alveolar contributions [CA(NO)(ppb)]. Several studies have demonstrated the potential significance of such an approach in children with asthma. However, techniques to partition eNO are variable, limiting comparisons among studies. The objective of this study is to examine the impact of the analysis interval (time or volume) on eNO plateau concentrations and the estimation of J' aw NO and CA(NO). In 30 children with mild to moderate asthma, spirometry and eNO at multiple flows (50, 100, and 200 ml/sec) were measured. The plateau concentration of eNO at each flow was determined using two different methods of analysis: (1) constant time interval and (2) constant volume interval. For both methods of analysis, a two-compartment model with axial diffusion was used to characterize J' aw NO and CA(NO). At a flow of 200 ml/sec, the time interval analysis predicts values for eNO that are smaller than the volume interval analysis. As a result, there are significant differences in CA(NO) between the methods of analysis (volume > time). When using the multiple flow technique to partition eNO, the method of analysis (constant time vs. constant volume interval) significantly affects the estimation of CA(NO), and thus potentially the assessment and interpretation of distal lung inflammation. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20082344     DOI: 10.1002/ppul.21182

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  8 in total

1.  Clinical study of multiple breath biomarkers of asthma and COPD (NO, CO(2), CO and N(2)O) by infrared laser spectroscopy.

Authors:  Joanne H Shorter; David D Nelson; J Barry McManus; Mark S Zahniser; Susan R Sama; Donald K Milton
Journal:  J Breath Res       Date:  2011-07-15       Impact factor: 3.262

2.  Spirometry effects on conventional and multiple flow exhaled nitric oxide in children.

Authors:  Sandrah P Eckel; William S Linn; Muhammad T Salam; Theresa M Bastain; Yue Zhang; Edward B Rappaport; Meng Liu; Kiros Berhane
Journal:  J Asthma       Date:  2014-08-28       Impact factor: 2.515

3.  Multiple-flow exhaled nitric oxide, allergy, and asthma in a population of older children.

Authors:  William S Linn; Edward B Rappaport; Sandrah P Eckel; Kiros T Berhane; Yue Zhang; Muhammad T Salam; Tracy M Bastain; Frank D Gilliland
Journal:  Pediatr Pulmonol       Date:  2013-05-17

4.  Traffic-related air pollution and alveolar nitric oxide in southern California children.

Authors:  Sandrah P Eckel; Zilu Zhang; Rima Habre; Edward B Rappaport; William S Linn; Kiros Berhane; Yue Zhang; Theresa M Bastain; Frank D Gilliland
Journal:  Eur Respir J       Date:  2016-01-21       Impact factor: 16.671

5.  Quantifying proximal and distal sources of NO in asthma using a multicompartment model.

Authors:  David A Shelley; James L Puckett; Steven C George
Journal:  J Appl Physiol (1985)       Date:  2010-01-21

6.  Short-term effects of airport-associated ultrafine particle exposure on lung function and inflammation in adults with asthma.

Authors:  Rima Habre; Hui Zhou; Sandrah P Eckel; Temuulen Enebish; Scott Fruin; Theresa Bastain; Edward Rappaport; Frank Gilliland
Journal:  Environ Int       Date:  2018-05-26       Impact factor: 13.352

7.  Bayesian estimation of physiological parameters governing a dynamic two-compartment model of exhaled nitric oxide.

Authors:  Patrick Muchmore; Edward B Rappaport; Sandrah P Eckel
Journal:  Physiol Rep       Date:  2017-08

8.  Alveolar nitric oxide and its role in pediatric asthma control assessment.

Authors:  Olaia Sardón; Paula Corcuera; Ane Aldasoro; Javier Korta; Javier Mintegui; José I Emparanza; Eduardo G Pérez-Yarza
Journal:  BMC Pulm Med       Date:  2014-08-04       Impact factor: 3.317

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.