Literature DB >> 20080903

Persistent iatrogenic atrial septal defect after a single-puncture, double-transseptal approach for pulmonary vein isolation using a remote robotic navigation system: results from a prospective study.

Andreas Rillig1, Udo Meyerfeldt, Markus Kunze, Ralf Birkemeyer, Tomislav Miljak, Sebastian Jäckle, Bajram Hajredini, Fabian Treusch, Werner Jung.   

Abstract

AIMS: Persistent iatrogenic atrial septal defect (iASD) after transseptal puncture for pulmonary vein isolation (PVI) has been described recently as a complication of PVI. No data exists evaluating systematically the incidence and clinical implications of iASDs after PVI using a remote robotic navigation system (RNS) with sheaths with a distinct larger outer diameter. METHODS AND
RESULTS: In this prospective study, 40 patients with either paroxysmal (n = 22, 55%) or persistent symptomatic atrial fibrillation were treated with circumferential PVI using an RNS. In all patients, a single-puncture, double-transseptal approach was used to access the left atrium. Transoesophageal echocardiography was performed before and the day after PVI as well as after a 3 and 6 months follow-up (FU). The day after ablation an iASD was detected in 38 of 40 (95%) patients with a mean diameter of 3.45 +/- 1.5 mm. At 6-month FU, the iASDs were closed in 30 of 39 (78.9%) patients. During the 6-month FU period, no patient died or suffered from cerebral or cardiac embolism.
CONCLUSION: After a single-puncture, double-transseptal approach for PVI using the RNS, iASDs show a high spontaneous closure rate of 78.9% after a 6-month FU period. Persistent iASDs following PVI with the RNS are not associated with an increased rate of paradoxical embolism or with relevant shunting.

Entities:  

Mesh:

Year:  2010        PMID: 20080903     DOI: 10.1093/europace/eup428

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  11 in total

1.  Long-term follow-up of iatrogenic atrial septal defect: after percutaneous mitral balloon valvuloplasty.

Authors:  Sule Korkmaz; Burcu Demirkan; Yesim Guray; Mehmet Birhan Yilmaz; Hatice Sasmaz
Journal:  Tex Heart Inst J       Date:  2011

2.  Remote robotic catheter ablation for atrial fibrillation: how fast is it learned and what benefits can be earned?

Authors:  Andreas Rillig; Udo Meyerfeldt; Ralf Birkemeyer; Fabian Treusch; Markus Kunze; Tomislav Miljak; Vlada Zvereva; Werner Jung
Journal:  J Interv Card Electrophysiol       Date:  2010-09-28       Impact factor: 1.900

3.  High rate of persistent iatrogenic atrial septal defect after single transseptal puncture for cryoballoon pulmonary vein isolation.

Authors:  Markus Linhart; Jessica T Werner; Florian Stöckigt; Annika T Kohlmann; Pia C Lodde; Lutz P T Linneborn; Thomas Beiert; Christoph Hammerstingl; Roger Borràs; Georg Nickenig; René P Andrié; Jan W Schrickel
Journal:  J Interv Card Electrophysiol       Date:  2018-03-24       Impact factor: 1.900

Review 4.  Catheter Ablation of Atrial Fibrillation in Patients with Hardware in the Heart - Septal Closure Devices, Mechanical Valves and More.

Authors:  Stefano Bartoletti; Pasquale Santangeli; Luigi DI Biase; Andrea Natale
Journal:  J Atr Fibrillation       Date:  2013-06-30

Review 5.  Comparing Antiarrhythmic Drugs and Catheter Ablation for Treatment of Atrial Fibrillation.

Authors:  Andreas Rillig; Tina Lin; Feifan Ouyang; Karl Heinz Kuck; Roland Richard Tilz
Journal:  J Atr Fibrillation       Date:  2013-06-30

6.  Experience matters: long-term results of pulmonary vein isolation using a robotic navigation system for the treatment of paroxysmal atrial fibrillation.

Authors:  Andreas Rillig; Tina Lin; Boris Schmidt; Britta Feige; Christian Heeger; Jascha Wegner; Erik Wissner; Andreas Metzner; Anita Arya; Shibu Mathew; Peter Wohlmuth; Feifan Ouyang; Karl-Heinz Kuck; Roland Richard Tilz
Journal:  Clin Res Cardiol       Date:  2015-07-22       Impact factor: 5.460

7.  Robotic ablation of atrial fibrillation with a new remote catheter system.

Authors:  Alexander Wutzler; Thomas Wolber; Abdul Shokor Parwani; Martin Huemer; Philipp Attanasio; Florian Blaschke; Laurent Haegeli; Wilhelm Haverkamp; Firat Duru; Leif-Hendrik Boldt
Journal:  J Interv Card Electrophysiol       Date:  2014-04-29       Impact factor: 1.900

8.  Robotic ablation of atrial fibrillation.

Authors:  Alexander Wutzler; Thomas Wolber; Wilhelm Haverkamp; Leif-Hendrik Boldt
Journal:  J Vis Exp       Date:  2015-05-29       Impact factor: 1.355

9.  A modified percutaneous atrial balloon septoplasty for difficult transseptal puncture.

Authors:  Siyu Wang; Lei Zhao; Yuxing Wang; Xiandong Yin; Xinchun Yang; Ye Liu
Journal:  Medicine (Baltimore)       Date:  2021-07-16       Impact factor: 1.817

10.  Ischemic Stroke or Systemic Embolism After Transseptal Ablation of Arrhythmias in Patients With Cardiac Implantable Electronic Devices.

Authors:  Malini Madhavan; Xiaoxi Yao; Lindsey R Sangaralingham; Samuel J Asirvatham; Paul A Friedman; Christopher J McLeod; Alan M Sugrue; Christopher V DeSimone; Peter A Noseworthy
Journal:  J Am Heart Assoc       Date:  2016-04-13       Impact factor: 5.501

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.