Literature DB >> 20080241

What humeri are suitable for comparative testing of suture anchors? An ultrastructural bone analysis and biomechanical study of ovine, bovine and human humeri and four different anchor types.

Matthias F Pietschmann1, Andreas Hölzer, Christine Rösl, Andreas Scharpf, Thomas Niethammer, Volkmar Jansson, Peter E Müller.   

Abstract

For testing of fixation devices such as suture anchors used in rotator cuff repair often animal bones are used. They are easily obtained, inexpensive and some have been found to be similar to human bone. But can we rely on the results drawn from these studies in our daily surgical practice? The purpose of this study was to compare the trabecular bone mineral density, the trabecular bone volume fraction and the cortical layer thickness in the greater tubercle in different species to evaluate their influence on primary stability of suture anchors under a cyclic loading protocol representing the physiologic forces placed on rotator cuff repairs in vivo. Bovine and ovine humeri are not suitable for suture anchor testing. The statistical significances for pullout forces between the anchors varied from species to species. Therefore, no very applicable information can be obtained from testing suture anchors in ovine or bovine humeri with regard to ultimate failure loads in human humeri. The ultimate failure load seems to depend mainly on the cortical thickness and on the subcortical trabecular bone quality. Copyright 2009 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20080241     DOI: 10.1016/j.jbiomech.2009.12.021

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Single- versus double-row repair for full-thickness rotator cuff tears using suture anchors. A systematic review and meta-analysis of basic biomechanical studies.

Authors:  Erik Hohmann; Anya König; Cor-Jacques Kat; Vaida Glatt; Kevin Tetsworth; Natalie Keough
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-12-21

2.  Does the Anchor Eye Alignment Affect the Performance of the Rotator Cuff Repair? A Biomechanical Study.

Authors:  Lara Locatelli; Cesar A Q Martins; Arthur P G Santos; Patricia O Cubillos; Carlos R M Roesler
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-02-01

3.  Comparisons of the surface micromotions of cementless femoral prosthesis in the horizontal and vertical levels: a network analysis of biomechanical studies.

Authors:  Bomin Wang; Qinghu Li; Jinlei Dong; Dongsheng Zhou; Fanxiao Liu
Journal:  J Orthop Surg Res       Date:  2020-07-31       Impact factor: 2.359

4.  The relationship between age, rotator cuff integrity, and osseous microarchitecture of greater tuberosity: Where should we put anchor?

Authors:  Erica Kholinne; Hyun Joo Lee; Sung Jung Kim; So Hyun Park; In-Ho Jeon
Journal:  Acta Orthop Traumatol Turc       Date:  2017-10-16       Impact factor: 1.511

  4 in total