Literature DB >> 20078702

The efficacy of R-Endo rotary NiTi and stainless-steel hand instruments to remove gutta-percha and Resilon.

G Fenoul1, G D Meless, F Pérez.   

Abstract

AIM: To evaluate the efficacy of the R-Endo rotary nickel titanium instrumentation system and hand instrumentation to remove gutta-percha or Resilon from root canals.
METHODOLOGY: Eighty single-rooted teeth with straight canals were selected, the pulp chamber was opened, and the canals prepared to a size 30, 0.04 taper. The teeth were divided randomly into two groups of 40 each for root filling with gutta-percha + MMSeal sealer or Resilon + RealSeal sealer. After storage, each group was divided into two subgroups, and material was removed with Hedström files or with R-Endo instrumentation. Times to reach the working length and to eliminate filling material were recorded. Root canal walls were examined using scanning electron microscope to evaluate material remnants on each third. The presence of material was measured according to a score scale. The Student's t-test was used to determine significant differences between mean values of time and remaining material (P < 0.05).
RESULTS: No significant differences occurred between thirds, material or removal technique regarding remaining filling debris (P > 0.05). However, times to reach the working length and for removal of filling were lower with R-Endo than with Hedström files (P < 0.0001).
CONCLUSIONS: Both instrumentation techniques left filling material inside the root canal and mainly in the apical third. There was no difference between the instrumentation techniques.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20078702     DOI: 10.1111/j.1365-2591.2009.01653.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  10 in total

1.  Comparative evaluation of retreatment techniques by using different file systems from oval-shaped canals.

Authors:  Rucheet Purba; Snehal S Sonarkar; Rajesh Podar; Shishir Singh; Shashank Babel; Gaurav Kulkarni
Journal:  J Conserv Dent       Date:  2020-10-10

2.  The efficacy of two rotary NiTi instruments and H-files to remove gutta-percha from root canals.

Authors:  Kerem-Engin Akpınar; Demet Altunbaş; Alper Kuştarcı
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-05-01

3.  In Vitro Comparison of Gutta-Percha Removal with H-File and ProTaper with or without Chloroform.

Authors:  Zohreh Khalilak; Mehdi Vatanpour; Bahareh Dadresanfar; Pouneh Moshkelgosha; Hamidreza Nourbakhsh
Journal:  Iran Endod J       Date:  2013-01-20

4.  Comparative Assessment of Canal Transportation, Dentin Loss, and Remaining Root Filling Material by Different Retreatment Files An In vitro Cross-Sectional Study.

Authors:  Afzal Ali; Prahlad Saraf; Laxmikant Kamatagi; Sandhya Khasnis
Journal:  Contemp Clin Dent       Date:  2021-03-20

5.  Influence of Passive Ultrasonic Irrigation on the Removal of Root Canal Filling Material in Straight Root Canals.

Authors:  Carlos Eduardo da Silveira Bueno; Marcos de Azevêdo Rios; Marcelo Santos Coelho; Alexandre Mascarenhas Villela; Alexandre Sigrist de Martin; Augusto Shoji Kato; Vanessa de Oliveira Alves; Rodrigo Sanches Cunha
Journal:  Eur Endod J       Date:  2017-05-08

6.  Comparative Evaluation of Efficacy of Protaper Universal Retreatment System, R-Endo System and Hedstrom File in Gutta Percha Removal During Root Canal Retreatment- An In Vitro Study.

Authors:  Aravind T Buranade; Youssef Abdullah Algarni; Adel Saeed N Alobaid; Mohammed Abdul Kader; Suheel Manzoor Baba; Ahamed Babiker Mohamed Ali
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13

7.  Efficacy of Three Different Methods in the Retreatment of Root Canals Filled with Resilon/Epiphany SE.

Authors:  Hasan Ramzi; Noushin Shokouhinejad; Mohammad Ali Saghiri; Ardavan Samieefard
Journal:  Iran Endod J       Date:  2010-11-15

8.  Efficacy of Two Rotary NiTi Instruments in Removal of Resilon/Epiphany Obturants.

Authors:  Bahareh Dadresanfar; Mahbubeh Iranmanesh; Pooneh Mohebbi; Payman Mehrvarzfar; Mehdi Vatanpour
Journal:  Iran Endod J       Date:  2012-10-13

9.  An in vitro CT Comparison of Gutta-Percha Removal with Two Rotary Systems and Hedstrom Files.

Authors:  Pankaj Yadav; Makonahalli Jaganath Bharath; Chickmagravalli Krishnegowda Sahadev; Praveen Kumar Makonahalli Ramachandra; Yogesh Rao; Ambereen Ali; Shahnawaz Mohamed
Journal:  Iran Endod J       Date:  2013-05-01

Review 10.  Resilon: a comprehensive literature review.

Authors:  Mehrdad Lotfi; Negin Ghasemi; Saeed Rahimi; Sepideh Vosoughhosseini; Mohammad Ali Saghiri; Atabak Shahidi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2013-08-30
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.