Literature DB >> 20078536

Computed tomography virtual intravascular endoscopy in the evaluation of fenestrated stent graft repair of abdominal aortic aneurysms.

Zhonghua Sun1, Bibombe P Mwipatayi, Yvonne B Allen, David E Hartley, Michael M D Lawrence-Brown.   

Abstract

BACKGROUND: This study aimed to investigate the diagnostic value of computed tomography virtual intravascular endoscopy (VIE) in the follow-up of patients with abdominal aortic aneurysm (AAA) treated with fenestrated stent grafts.
METHODS: A total of 19 patients (17 males and 2 females; mean age: 75 years) with AAA undergoing fenestrated stent grafts were retrospectively studied. Pre- and post-fenestration computed tomography data were reconstructed for the generation of VIE images of aortic ostia and fenestrated stents and compared with two-dimensional axial and multiplanar reformation (MPR) images. Serum creatinine was measured pre and post fenestration to evaluate the renal function.
RESULTS: The mean intra-aortic length measured by VIE, two-dimensional axial and MPR were 4.7, 4.4 and 4.6 mm, respectively, for the right renal stent; 5.0, 4.9 and 5.0 mm, respectively, for the left renal stent; and 5.9, 6.0 and 6.0 mm, respectively, for the superior mesenteric artery stent. Comparisons of these measurements did not show significant difference (P > 0.05). The mean diameters of renal artery ostia measured on VIE visualization pre and post fenestration were 9.2 x 8.3 and 10 x 8.9 mm for the right renal ostium; 8.3 x 7.1 and 9.9 x 8.9 mm for the left renal ostium, with significant changes observed (P < 0.01). No renal dysfunction was observed in this group.
CONCLUSION: VIE is a valuable visualization tool in the follow-up of fenestrated stent graft repair of AAA by providing intraluminal appearance of fenestrated stents and measuring the length of stent protrusion.

Entities:  

Mesh:

Year:  2009        PMID: 20078536     DOI: 10.1111/j.1445-2197.2009.05112.x

Source DB:  PubMed          Journal:  ANZ J Surg        ISSN: 1445-1433            Impact factor:   1.872


  3 in total

Review 1.  Radiology of advanced EVAR techniques in complex abdominal aortic aneurysms.

Authors:  Uei Pua; Kongteng Tan
Journal:  Eur Radiol       Date:  2011-09-17       Impact factor: 5.315

2.  Added Value of Computed Tomography Virtual Intravascular Endoscopy in the Evaluation of Coronary Arteries with Stents or Plaques.

Authors:  Patricia Wanping Wu; Pei-Kwei Tsay; Zhonghua Sun; Syu-Jyun Peng; Chia-Yen Lee; Ming-Yi Hsu; Yu-Shien Ko; I-Chang Hsieh; Ming-Shien Wen; Yung-Liang Wan
Journal:  Diagnostics (Basel)       Date:  2022-02-03

Review 3.  Coronary CT angiography in the quantitative assessment of coronary plaques.

Authors:  Zhonghua Sun; Lei Xu
Journal:  Biomed Res Int       Date:  2014-08-05       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.