Literature DB >> 20074539

Qualitative and quantitative comparison of brand name and generic protein pharmaceuticals using isotope tags for relative and absolute quantification and matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry.

Hongping Ye1, John Hill, John Kauffman, Xianlin Han.   

Abstract

The capability of iTRAQ (isotope tags for relative and absolute quantification) reagents coupled with matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-TOF/TOF-MS) as a qualitative and quantitative technique for the analysis of complicated protein pharmaceutical mixtures was evaluated. Mixtures of Somavert and Miacalcin with a small amount of bovine serum albumin (BSA) as an impurity were analyzed. Both Somavert and Miacalcin were qualitatively identified, and BSA was detected at levels as low as 0.8mol%. Genotropin and Somavert were compared in a single experiment, and all of the distinct amino acid residues from the two proteins were readily identified. Four somatropin drug products (Genotropin, Norditropin, Jintropin, and Omnitrope) were compared using the iTRAQ/MALDI-MS method to determine the similarity between their primary structures and quantify the amount of protein in each product. All four product samples were well labeled and successfully compared when a filtration cleanup step preceded iTRAQ labeling. The quantitative accuracy of the iTRAQ method was evaluated. In all cases, the accuracy of experimentally determined protein ratios was higher than 90%, and the relative standard deviation (RSD) was less than 10%. The iTRAQ and global internal standard technology (GIST) methods were compared, and the iTRAQ method provided both higher sequence coverage and enhanced signal intensity. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20074539     DOI: 10.1016/j.ab.2010.01.012

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  4 in total

1.  Comparability analysis of protein therapeutics by bottom-up LC-MS with stable isotope-tagged reference standards.

Authors:  Anton V Manuilov; Czeslaw H Radziejewski; David H Lee
Journal:  MAbs       Date:  2011-07-01       Impact factor: 5.857

2.  Supercritical synthesis of poly (2-dimethylaminoethyl methacrylate)/ferrite nanocomposites for real-time monitoring of protein release.

Authors:  Gunjan Bisht; M G H Zaidi
Journal:  Drug Deliv Transl Res       Date:  2015-06       Impact factor: 4.617

3.  Protein quantitation using iTRAQ: Review on the sources of variations and analysis of nonrandom missingness.

Authors:  Ruiyan Luo; Hongyu Zhao
Journal:  Stat Interface       Date:  2012-01-01       Impact factor: 0.582

Review 4.  Mass spectrometry methodology in lipid analysis.

Authors:  Lin Li; Juanjuan Han; Zhenpeng Wang; Jian'an Liu; Jinchao Wei; Shaoxiang Xiong; Zhenwen Zhao
Journal:  Int J Mol Sci       Date:  2014-06-11       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.