Literature DB >> 2007288

Oxygen transmissibility of disposable hydrogel contact lenses.

B A Weissman1, S D Schwartz, D A Lee.   

Abstract

We measured the central and mid-peripheral thicknesses of three "disposable" hydrogel contact lens designs of varying powers. These measurements allowed calculation of the areal average lens thicknesses (over a central 6 mm chord), which in turn allowed calculation of predicted oxygen transmissibility (Dk/L) for the lenses studied (using previously reported values for measured oxygen permeability [Dk] of these materials). Dk/L values for the disposable hydrogel lenses tested were found to range from 9 to 17 x 10(-9) cm mL O2/sec mL mmHg.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2007288

Source DB:  PubMed          Journal:  CLAO J        ISSN: 0733-8902