Validation of Panasonic EW3106 and EW3109 devices for blood pressure measurement according to the International Protocol.

Elisa Bonso1, Francesca Dorigatti, Paolo Palatini.   

Abstract

To determine the accuracy of the EW3106 and EW3109 devices for blood pressure measurement at the upper arm developed by Panasonic. Device evaluations were performed according to the European Society of Hypertension requirements, which are based on four zones of accuracy differing from the mercury standard by 5, 10, 15 mmHg, or more. Both devices passed all three phases of the protocol for systolic blood pressure (SBP) and diastolic blood pressure (DBP). Mean blood pressure difference between the EW3106 monitor and observers was -0.9+/-5.8 mmHg for SBP and 0.1+/-4.8 mmHg for DBP. Mean differences for the EW3109 monitor were -2.1+/-6.5 mmHg and -0.3+/-4.7 mmHg, respectively. In multivariable analyses, the SBP and DBP discrepancies between both devices and observers were unrelated to age and arm circumference, and were inversely related to blood pressure level. These data show that the Panasonic EW3106 and EW 3109 monitors satisfy the recommended European Society of Hypertension accuracy levels for SBP and DBP.

Entities:  

Mesh:

Year:  2010        PMID: 20071978     DOI: 10.1097/MBP.0b013e32833531b3

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  4 in total

1.  Profile of interdialytic ambulatory blood pressure in a cohort of Chinese patients.

Authors:  W Liu; H Ye; B Tang; Z Song; Z Sun; P Wen; J Yang
Journal:  J Hum Hypertens       Date:  2014-06-12       Impact factor: 3.012

2.  Poor agreement between dialysis unit blood pressure and interdialytic ambulatory blood pressure.

Authors:  Wenjin Liu; Jing Niu; Chunsun Dai; Junwei Yang
Journal:  J Clin Hypertens (Greenwich)       Date:  2014-08-26       Impact factor: 3.738

3.  Age, sex, and the vascular contributors to cerebral pulsatility and pulsatile damping.

Authors:  Wesley K Lefferts; Jacob P DeBlois; Jacqueline A Augustine; Allison P Keller; Kevin S Heffernan
Journal:  J Appl Physiol (1985)       Date:  2020-09-17

4.  Manipulation of arterial stiffness, wave reflections, and retrograde shear rate in the femoral artery using lower limb external compression.

Authors:  Kevin S Heffernan; Wesley K Lefferts; Ari G Kasprowicz; Brendan J Tarzia; Dick H Thijssen; Tom D Brutsaert
Journal:  Physiol Rep       Date:  2013-07-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.