Literature DB >> 20065856

Handling a high relaxivity contrast material for dynamic breast MR imaging using higher thresholds for the initial enhancement.

Luca A Carbonaro1, Nicola Verardi, Giovanni Di Leo, Francesco Sardanelli.   

Abstract

OBJECTIVES: To increase specificity of gadobenate dimeglumine-enhanced breast magnetic resonance (MR) imaging without losing sensitivity.
MATERIALS AND METHODS: IRB approval was obtained for this retrospective study and informed consent was waived. Sixty-eight patients with 73 breast lesions underwent dynamic breast 1.5-T MR imaging with 0.1 mmol/kg of gadobenate dimeglumine and 103 or 111-second temporal resolution. A score system based on shape (round/oval/lobular = 0, linear/dendritic/stellate = 1), margins (defined = 0, undefined = 1), pattern (homogeneous = 0, inhomogeneous = 1, rim = 2), kinetics (continuous = 0, plateau = 1, washout = 2), and initial enhancement was used. Initial enhancement was evaluated with standard (<50% = 0, 50%-100% = 1, >100% = 2) or adjusted (<180% = 0, 180%-240% = 1, >240% = 2) thresholds. Scores 0-2, 3, 4 or 5, and from 6 to 8 were considered as equivalent to Breast Imaging Reporting and Data System 2, 3, 4, and 5, respectively. Pathologic examination (core-, vacuum-assisted, or surgical biopsy) served as a reference standard. Nonparametric tests were used.
RESULTS: At histopathology, 52 lesions were malignant, 21 were benign. The initial enhancement for benign lesions was 141% +/- 65% (mean +/- SD), whereas for malignant lesions it was 210% +/- 80% (P = 0.001). The median multifactorial score for benign lesions was 4 using the standard thresholds and 3 using the adjusted thresholds (P < 0.001) whereas for malignant lesions it was 7 and 6, respectively (P < 0.001). Specificity increased from 38% with standard thresholds to 71% with adjusted thresholds (gain of 33%; P = 0.016); positive predictive value 80% and 90%, negative predictive value 100% and 100%, and accuracy 82% and 92%, respectively. Sensitivity was 100% for both thresholds.
CONCLUSIONS: Specificity of gadobenate dimeglumine-enhanced breast MR imaging can be increased without limiting its high sensitivity.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20065856     DOI: 10.1097/RLI.0b013e3181cc2929

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  1 in total

Review 1.  Use of contrast agents in oncological imaging: magnetic resonance imaging.

Authors:  Giovanni Morana; Christian Cugini; Giuliano Scatto; Riccardo Zanato; Michele Fusaro; Alberto Dorigo
Journal:  Cancer Imaging       Date:  2013-09-23       Impact factor: 3.909

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.