The dual-wave bolus feature in type 1 diabetes adult users of insulin pumps.

Tomasz Klupa1, Jan Skupien, Katarzyna Cyganek, Barbara Katra, Jacek Sieradzki, Maciej T Malecki.   

Abstract

One of the attributes of CSII (continuous subcutaneous insulin infusion) is its ability to tailor prandial insulin delivery to the composition of a meal and anticipated glycemic effects. The dual-wave bolus (DWB) is a tool implemented in contemporary insulin pumps that delivers a combination of an instant insulin bolus followed by a square bolus (SB) infused over several hours. We assessed the effectiveness of DWB in 56 adult patients with type 1 diabetes (T1DM) who were on continuous subcutaneous insulin infusion via insulin pump for at least 2 years. We divided patients into frequent (DWB+, n = 32) and infrequent (DWB-, n = 24) DWB users (>20% vs. <20% of daily bolus dose delivered as SB). CSII implementation resulted in a decrease of adjusted HbA1c level by 0.80% (95% CI 0.67-0.93, P < 0.0001) and adjusted mean glycemia by 18.4 mg/dl (95% CI 15.3-21.4, P < 0.0001) in the whole cohort within the first year of observation. It was sustained in the second year, but without further improvement. Frequent DWB use was associated with male sex (59% vs. 17%, p = 0.001) and shorter duration of T1DM (3.4 vs. 11.3 yrs, p < 0.0001), but not with patients' age (25.7 vs. 27.0 years, P = 0.6). DWB+ patients improved their HbA1c by 0.45% more (95% CI 0.20-0.71, P = 0.0009) than DWB- individuals. In conclusion, DWB might be a tool potentially helping to improve glycemic control in T1DM adult users of insulin pumps. Male patients and those with a shorter duration of diabetes seem to use it more willingly.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20063022     DOI: 10.1007/s00592-009-0173-9

Source DB:  PubMed          Journal:  Acta Diabetol        ISSN: 0940-5429            Impact factor:   4.280


  3 in total

1.  Commentary on "Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects".

Authors:  Paolo Rossetti; Josep Vehí; Ana Revert; Remei Calm; Jorge Bondia
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

2.  Three-year comparison of subcutaneous insulin pump treatment with multi-daily injections on HbA1c, its variability and hospital burden of children with type 1 diabetes.

Authors:  Wojciech Fendler; Anna Iza Baranowska; Beata Mianowska; Agnieszka Szadkowska; Wojciech Mlynarski
Journal:  Acta Diabetol       Date:  2011-10-01       Impact factor: 4.280

3.  Impact of continuous glucose monitoring on quality of life, treatment satisfaction, and use of medical care resources: analyses from the SWITCH study.

Authors:  E Hommel; B Olsen; T Battelino; I Conget; I Schütz-Fuhrmann; R Hoogma; U Schierloh; N Sulli; H Gough; J Castañeda; S de Portu; J Bolinder
Journal:  Acta Diabetol       Date:  2014-07-19       Impact factor: 4.280

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.