Literature DB >> 20060627

Biomechanical comparison of hallux valgus correction using the proximal chevron osteotomy fixed with a medial locking plate and the Ludloff osteotomy fixed with two screws.

Aaron T Scott1, James K DeOrio, Harvey E Montijo, Richard R Glisson.   

Abstract

BACKGROUND: For moderate-to-severe hallux valgus deformities with a 1-2 intermetatarsal angle in excess of 15 degrees , a proximal first metatarsal osteotomy is indicated. The ideal osteotomy has yet to be defined, but should inherently limit the incidence of dorsal malunion and allow for early ambulation. The present study evaluates the mechanical integrity of two popular first metatarsal osteotomies.
METHODS: Ten matched pairs of fresh-frozen cadaveric first metatarsals were harvested. In one metatarsal from each pair, a Ludloff osteotomy was created and fixed with two cannulated 3.5mm screws. In the contralateral first metatarsal, a proximal chevron osteotomy was performed and subsequently fixed with a medially applied locking plate. All specimens were mounted within an Instron 1321 servohydraulic materials testing machine and subjected to a plantar-to-dorsal cantilever bending protocol for 1000 cycles.
FINDINGS: Two of ten Ludloff osteotomies failed prior to completion of 1000 loading cycles by fracture at the distal screw site, whereas six of ten proximal chevrons failed prior to the 1000th cycle. The mode of failure in this group was by cut-out of the plantar-proximal screw. The bending stiffness of the Ludloff osteotomy exceeded that of the proximal chevron at all measurement points between the 1st and 200th load cycles (P<0.05). After 200 cycles, an inadequate number of plate constructs survived to allow statistical comparison.
INTERPRETATION: The results of the present study indicate that the proximal chevron osteotomy fixed with a medially based locking plate exhibits mechanical properties inferior to those of the Ludloff osteotomy under the tested conditions.

Entities:  

Mesh:

Year:  2010        PMID: 20060627     DOI: 10.1016/j.clinbiomech.2009.12.006

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  6 in total

Review 1.  The Ludloff osteotomy: a review of current concepts.

Authors:  Deborah A Castaneda; Mark S Myerson; Steven K Neufeld
Journal:  Int Orthop       Date:  2013-08-17       Impact factor: 3.075

2.  Biomechanical analysis of two fixation methods for proximal chevron osteotomy of the first metatarsal.

Authors:  Reinhard Schuh; Jochen Gerhard Hofstaetter; Emir Benca; Madeleine Willegger; Gobert von Skrbensky; Shahin Zandieh; Axel Wanivenhaus; Johannes Holinka; Reinhard Windhager
Journal:  Int Orthop       Date:  2014-02-04       Impact factor: 3.075

Review 3.  Angular correction and complications of proximal first metatarsal osteotomies for hallux valgus deformity.

Authors:  Reinhard Schuh; Madeleine Willegger; Johannes Holinka; Robin Ristl; Reinhard Windhager; Axel H Wanivenhaus
Journal:  Int Orthop       Date:  2013-07-25       Impact factor: 3.075

4.  Biomechanical in vitro - stability testing on human specimens of a locking plate system against conventional screw fixation of a proximal first metatarsal lateral displacement osteotomy.

Authors:  Heino Arnold; Christina Stukenborg-Colsman; Christof Hurschler; Frank Seehaus; Evgenij Bobrowitsch; Hazibullah Waizy
Journal:  Open Orthop J       Date:  2012-04-04

5.  Weight-bearing recommendations after first metatarsophalangeal joint arthrodesis fixation: a biomechanical comparison.

Authors:  Bradley Campbell; Patrick Schimoler; Sudhir Belagaje; M C Miller; S F Conti
Journal:  J Orthop Surg Res       Date:  2017-02-06       Impact factor: 2.359

6.  Biomechanical Comparison Study of Three Fixation Methods for Proximal Chevron Osteotomy of the First Metatarsal in Hallux Valgus.

Authors:  Jin Su Kim; Hun Ki Cho; Ki Won Young; Ji Soo Kim; Kyung Tai Lee
Journal:  Clin Orthop Surg       Date:  2017-11-10
  6 in total