Literature DB >> 20059263

Monte Carlo study of global interference cancellation by multidistance measurement of near-infrared spectroscopy.

Shinji Umeyama1, Toru Yamada.   

Abstract

The performance of near-infrared spectroscopy is sometimes degraded by the systemic physiological interference in the extracerebral layer. There is some systemic interference, which is highly correlated with the functional response evoked by a task execution. This kind of interference is difficult to remove by using ordinary techniques. A multidistance measurement method is one of the possible solutions for this problem. The multidistance measurement method requires estimation parameters derived from partial pathlength values of tissue layers to calculate an absorption coefficient change from a temporal absorbance change. Because partial path lengths are difficult to obtain, experimentally, we estimated them by a Monte Carlo simulation based on a five-layered slab model of a human adult head. Model parameters such as thickness and the transport scattering coefficient of each layer depend on a subject and a measurement position; thus, we assumed that these parameters obey normal distributions around standard parameter values. We determined the estimation parameters that provide a good separation performance in average for the model parameter distribution. The obtained weighting is robust to model parameter deviation and provides smaller errors on average compared to the parameters, which are determined without considering parameter distribution.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20059263     DOI: 10.1117/1.3275466

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  11 in total

1.  Multiregional functional near-infrared spectroscopy reveals globally symmetrical and frequency-specific patterns of superficial interference.

Authors:  Yujin Zhang; Fulun Tan; Xu Xu; Lian Duan; Hanli Liu; Fenghua Tian; Chao-Zhe Zhu
Journal:  Biomed Opt Express       Date:  2015-07-08       Impact factor: 3.732

2.  Short separation regression improves statistical significance and better localizes the hemodynamic response obtained by near-infrared spectroscopy for tasks with differing autonomic responses.

Authors:  Meryem A Yücel; Juliette Selb; Christopher M Aasted; Mike P Petkov; Lino Becerra; David Borsook; David A Boas
Journal:  Neurophotonics       Date:  2015-09-11       Impact factor: 3.593

3.  Near-infrared spectroscopy determined cerebral oxygenation with eliminated skin blood flow in young males.

Authors:  Ai Hirasawa; Takahito Kaneko; Naoki Tanaka; Tsukasa Funane; Masashi Kiguchi; Henrik Sørensen; Niels H Secher; Shigehiko Ogoh
Journal:  J Clin Monit Comput       Date:  2015-05-29       Impact factor: 2.502

4.  Short separation channel location impacts the performance of short channel regression in NIRS.

Authors:  Louis Gagnon; Robert J Cooper; Meryem A Yücel; Katherine L Perdue; Douglas N Greve; David A Boas
Journal:  Neuroimage       Date:  2011-09-08       Impact factor: 6.556

5.  Improved recovery of the hemodynamic response in diffuse optical imaging using short optode separations and state-space modeling.

Authors:  Louis Gagnon; Katherine Perdue; Douglas N Greve; Daniel Goldenholz; Gayatri Kaskhedikar; David A Boas
Journal:  Neuroimage       Date:  2011-03-06       Impact factor: 6.556

6.  Further improvement in reducing superficial contamination in NIRS using double short separation measurements.

Authors:  Louis Gagnon; Meryem A Yücel; David A Boas; Robert J Cooper
Journal:  Neuroimage       Date:  2013-02-09       Impact factor: 6.556

7.  Signal Processing in Functional Near-Infrared Spectroscopy (fNIRS): Methodological Differences Lead to Different Statistical Results.

Authors:  Mischa D Pfeifer; Felix Scholkmann; Rob Labruyère
Journal:  Front Hum Neurosci       Date:  2018-01-08       Impact factor: 3.169

8.  Evoked Hemodynamic Response Estimation to Auditory Stimulus Using Recursive Least Squares Adaptive Filtering with Multidistance Measurement of Near-Infrared Spectroscopy.

Authors:  Yan Zhang; Xin Liu; Dan Liu; Chunling Yang; Qisong Wang; Jinwei Sun; Kuanquan Wang
Journal:  J Healthc Eng       Date:  2018-03-29       Impact factor: 2.682

9.  A validation method for near-infrared spectroscopy based tissue oximeters for cerebral and somatic tissue oxygen saturation measurements.

Authors:  Paul B Benni; David MacLeod; Keita Ikeda; Hung-Mo Lin
Journal:  J Clin Monit Comput       Date:  2017-04-03       Impact factor: 2.502

10.  Detector location selection based on VIP analysis in near-infrared detection of dural hematoma.

Authors:  Qiuming Sun; Yanjun Zhang; Jun Ma; Feng Tian; Huiquan Wang; Dongyuan Liu
Journal:  Saudi J Biol Sci       Date:  2017-11-16       Impact factor: 4.219

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.