| Literature DB >> 20056031 |
Xiaolin Hou1, Yonggang Li, Guojuan Wu, Lei Wang, Miao Hong, Yongnin Wu.
Abstract
A simple high-performance liquid chromatography method was developed for quantitative determination of para red, Sudan I, Sudan II, Sudan III, Sudan IV, canthaxanthin, and astaxanthin in feedstuff. The sample was extracted using acetonitrile and cleaned up on a C(18) SPE column. The residues were analyzed using ultra-performance liquid chromatography coupled to a diode array detector at 500 nm. The mobile phase was acetonitrile-formic acid-water with a gradient elution condition. The external standard curves were calibrated. The mean recoveries of the seven colorants were 62.7-91.0% with relative standard deviation 2.6-10.4% (intra-day) and 4.0-13.2% (inter-day). The detection limits were in the range of 0.006-0.02 mg/kg.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20056031 DOI: 10.1093/chromsci/48.1.22