Exposure to anaesthetic trace gases during general anaesthesia: CobraPLA vs. LMA classic.

K Schebesta1, V Lorenz, E M Schebesta, K Hörauf, M Gruber, O Kimberger, A Chiari, M Frass, P Krafft.   

Abstract

BACKGROUND: To prospectively investigate the performance, sealing capacity and operating room (OR) staff exposure to waste anaesthetic gases during the use of the Cobra perilaryngeal airway (CobraPLA) compared with the laryngeal mask airway classic (LMA).
METHODS: Sixty patients were randomly assigned to the CobraPLA or the LMA group. Insertion time, number of insertion attempts and airway leak pressures were assessed after induction of anaesthesia. Occupational exposure to nitrous oxide (N(2)O) and Sevoflurane (SEV) was measured at the anaesthetists' breathing zone and the patients' mouth using a photoacoustic infrared spectrometer.
RESULTS: N(2)O waste gas concentrations differed significantly in the anaesthetist's breathing zone (11.7+/-7.2 p.p.m. in CobraPLA vs. 4.1+/-4.3 p.p.m. in LMA, P=0.03), whereas no difference could be shown in SEV concentrations. Correct CobraPLA positioning was possible in 28 out of 30 patients (more than one attempt necessary in five patients). Correct positioning of the LMA classic was possible in all 30 patients (more than one attempt in three patients). Peak airway pressure was higher in the CobraPLA group (16+/-3 vs. 14+/-2 cmH(2)O, P=0.01). The average leak pressure of the CobraPLA was 24+/-4 cmH(2)O, compared with 20+/-4 cmH(2)O of the LMA classic (P<0.001; all values means+/-SD).
CONCLUSION: Despite higher airway seal pressures, the CobraPLA caused higher intraoperative N(2)O trace concentrations in the anaesthetists' breathing zone.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20055764     DOI: 10.1111/j.1399-6576.2009.02194.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  4 in total

Review 1.  Waste anesthetic gas exposure and strategies for solution.

Authors:  Hai-Bo Deng; Feng-Xian Li; Ye-Hua Cai; Shi-Yuan Xu
Journal:  J Anesth       Date:  2018-02-05       Impact factor: 2.078

2.  Does standing or sitting position of the anesthesiologist in the operating theatre influence sevoflurane exposure during craniotomies?

Authors:  Péter Sárkány; Béla Tankó; Éva Simon; Judit Gál; Béla Fülesdi; Csilla Molnár
Journal:  BMC Anesthesiol       Date:  2016-12-01       Impact factor: 2.217

3.  Cobra-PLA provides higher oropharyngeal leak pressure than LMA-Classic and LMA-Unique: A meta-analysis with 22 studies.

Authors:  Yuan Tan; Guangyou Duan; Qin Chen; Feng Chen; Hong Li
Journal:  Medicine (Baltimore)       Date:  2019-06       Impact factor: 1.817

4.  Photoacoustic gas monitoring for anesthetic gas pollution measurements and its cross-sensitivity to alcoholic disinfectants.

Authors:  Jennifer Herzog-Niescery; Thomas Steffens; Martin Bellgardt; Andreas Breuer-Kaiser; Philipp Gude; Heike Vogelsang; Thomas Peter Weber; Hans-Martin Seipp
Journal:  BMC Anesthesiol       Date:  2019-08-09       Impact factor: 2.217

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.