Literature DB >> 20054767

Asymmetric dimethylarginine levels in patients with coronary artery ectasia.

Serkan Cay1, Goksel Cagirci, Murat Akcay, Ozlem Karakurt, Erkan Kahraman, Nuray Yazihan, Aytun Canga, Ramazan Akdemir, Sinan Aydogdu.   

Abstract

BACKGROUND: Endothelial dysfunction might be one of the pathophysiological mechanisms in the development of coronary artery ectasia (CAE) although the exact mechanisms have not yet been demonstrated. Asymmetric dimethylarginine (ADMA), an endogenous competitive inhibitor of nitric oxide synthase, is also related to endothelial and structural dysfunction. AIM: To asses the relationship between CAE and ADMA plasma concentrations.
METHODS: Thirty patients with CAE in a mean age of 55.5 +/- 3.6 years and 40 patients with normal coronary arteries in a mean age of 53.3 +/- 11.6 years were studied. The ADMA levels of all patients were analysed by ELISA method.
RESULTS: The mean ADMA level in the CAE group was found to be significantly higher than the mean ADMA level in the normal coronary artery group (2.26 +/- 0.47 vs. 1.43 +/- 0.40 micromol/l, p < 0.001). The elevated ADMA level (> 1.80 micromol/l) was present in 83.0% of patients from the CAE group and 25.0% of patients from the normal coronary artery group (p < 0.001). Having an increased ADMA level enhanced the risk of CAE 15-fold. The multiple-adjusted OR of the risk of CAE was 18.71 (95% CI 4.95-70.68) for the higher ADMA level compared to the lower level.
CONCLUSION: Asymmetric dimethylarginine level is significantly associated with the presence of coronary artery ectasia. These findings suggest that increased ADMA level may be associated with endothelial dysfunction leading to the development of coronary artery ectasia.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20054767

Source DB:  PubMed          Journal:  Kardiol Pol        ISSN: 0022-9032            Impact factor:   3.108


  2 in total

1.  Among Ectasia Patients with Coexisting Coronary Artery Disease, TIMI Frame Count Correlates with Ectasia Size and Markis Type IV Is the Commonest.

Authors:  Hasahya Tony; Kai Meng; Bangwei Wu; Qiutang Zeng
Journal:  Cardiol Res Pract       Date:  2015-02-03       Impact factor: 1.866

2.  Serum nitric oxide levels in patients with coronary artery ectasia.

Authors:  Adalet Gürlek; Kerim Esenboğa; Özgür Ulaş Özcan; Ömer Faruk Çiçek; Pelin Arıbal Ayral; Güzin Özelçi Kavas; Çetin Erol
Journal:  Anatol J Cardiol       Date:  2016-04-25       Impact factor: 1.596

  2 in total