Literature DB >> 20054195

Accuracy of bioelectrical impedance consumer devices for measurement of body composition in comparison to whole body magnetic resonance imaging and dual X-ray absorptiometry.

Anja Bosy-Westphal1, Wiebke Later, Britta Hitze, Tetsuya Sato, Elke Kossel, Claus-Christian Gluer, Martin Heller, Manfred James Muller.   

Abstract

OBJECTIVE: To compare body composition determined by bioelectrical impedance (BIA) consumer devices against criterion estimates determined by whole body magnetic resonance imaging (MRI) and dual energy X-ray absorptiometry (DXA) in healthy normal weight, overweight and obese adults.
METHODS: In 106 adults (54 females, 52 males, age 54.2 +/- 16.1 years, BMI 25.8 +/- 4.4 kg/m(2)) fat mass (FM), skeletal muscle mass (SM), total body bone-free lean mass (TBBLM), and level of visceral fat mass (VF) were estimated by 3 single-frequency bipedal (foot-to-foot) and one tretrapolar BIA device, and compared to body composition measured by MRI and DXA. Bland-Altman and simple linear regression analyses were used to determine agreement between methods.
RESULTS: %FMDXA, SMMRI or TBBLMDXA showed good relative and absolute agreement with two bipolar and one tetrapolar instrument (r(2) = 0.92-0.96; all p < 0.001; mean bias <1.5 %FM and <1 kg SM or TBBLM) and less relative and absolute agreement for another bipolar device (r(2) = 0.82 and 0.84, mean bias approximately 3 %FM and approximately 3 kg SM). The 95% limits of agreement (bias +/- 2 SD) were narrowest for the tetrapolar device (-6.59 to 4.61 %FM and -4.62 to 4.74 kg SM) and widest for bipolar instruments (up to -14.54 to 8.58 %FM and -9.52 to 3.92 kg SM). Systematic biases for %FM were found for all bipedal devices, but not for the tetrapolar instrument.
CONCLUSION: Because of the lower agreement between foot-to-foot BIA and DXA or MRI for the assessment of body composition in individuals, tetrapolar electrode arrangement should be preferred for individual or public use. Bipolar devices provide accurate results for field studies with group estimation.

Entities:  

Mesh:

Year:  2008        PMID: 20054195      PMCID: PMC6452160          DOI: 10.1159/000176061

Source DB:  PubMed          Journal:  Obes Facts        ISSN: 1662-4025            Impact factor:   3.942


  60 in total

Review 1.  Dietary management of IBD--insights and advice.

Authors:  Emma P Halmos; Peter R Gibson
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2015-02-03       Impact factor: 46.802

Review 2.  The clinical importance of visceral adiposity: a critical review of methods for visceral adipose tissue analysis.

Authors:  A Shuster; M Patlas; J H Pinthus; M Mourtzakis
Journal:  Br J Radiol       Date:  2011-09-21       Impact factor: 3.039

3.  Percent Body Fat Measured by Bioelectrical Impedance is Not Associated with Colorectal Adenoma Status.

Authors:  David J Frantz; Seth D Crockett; Joseph A Galanko; Robert S Sandler
Journal:  J Gastroenterol Hepatol Res       Date:  2013

4.  Measuring body composition using the bioelectrical impedance method can predict the outcomes of gemcitabine-based chemotherapy in patients with pancreatobiliary tract cancer.

Authors:  Mami Muramatsu; Aya Tsuchiya; Seiko Ohta; Yukie Iijima; Miyuki Maruyama; Yoshiko Onodera; Megumi Hagihara; Naoki Nakaya; Itaru Sato; Kenji Omura; Soichiro Ueno; Hideo Nakajima
Journal:  Oncol Lett       Date:  2015-10-16       Impact factor: 2.967

5.  Yoga in Women With Abdominal Obesityߞa Randomized Controlled Trial.

Authors:  Holger Cramer; Meral Sushila Thoms; Dennis Anheyer; Romy Lauche; Gustav Dobos
Journal:  Dtsch Arztebl Int       Date:  2016-09-30       Impact factor: 5.594

6.  Changes in body composition in unilateral vestibular hypofunction: relationships between bioelectrical impedance analysis and neuro-otological parameters.

Authors:  Alessandro Micarelli; Andrea Viziano; Ivan Granito; Riccardo Xavier Micarelli; Alessio Felicioni; Marco Alessandrini
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-01-03       Impact factor: 2.503

7.  Sleeve Gastrectomy and Roux-en-Y Gastric Bypass Lead to Comparable Changes in Body Composition after Adjustment for Initial Body Mass Index.

Authors:  Mirko Otto; Mohamad Elrefai; Johannes Krammer; Christel Weiß; Peter Kienle; Till Hasenberg
Journal:  Obes Surg       Date:  2016-03       Impact factor: 4.129

8.  Association of waist and hip circumferences with the presence of hypertension and pre-hypertension in young South African adults.

Authors:  Benedicta N Nkeh-Chungag; Thozama H Mxhosa; Papama N Mgoduka
Journal:  Afr Health Sci       Date:  2015-09       Impact factor: 0.927

9.  Plasma cortisol levels in response to a cold pressor test did not predict appetite or ad libitum test meal intake in obese women.

Authors:  Allan Geliebter; Charlisa D Gibson; Dominica B Hernandez; Deniz Atalayer; Anne Kwon; Michelle I Lee; Nandini Mehta; Donna Phair; Marci E Gluck
Journal:  Appetite       Date:  2012-09-13       Impact factor: 3.868

10.  The Relationship between Overweight and Overactive Bladder Symptoms.

Authors:  Magdaléna Hagovska; Ján Švihra; Alena Buková; Agata Horbacz; Dana Dračková; Ján Lupták; Ján Švihra
Journal:  Obes Facts       Date:  2020-05-12       Impact factor: 3.942

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.