Literature DB >> 20051923

A Comparison of fixed-hole and slotted-hole dynamic plates for anterior cervical discectomy and fusion.

Soon-Woo Hong1, Sang-Ho Lee, Larry T Khoo, Seung-Hwan Yoon, Langston T Holly, Arya Nick Shamie, Jeffrey C Wang.   

Abstract

STUDY
DESIGN: A retrospective review of clinical data at 1 institution was performed.
OBJECTIVES: To compare the clinical and radiologic outcomes between fixed-hole and slotted-hole dynamic cervical plates. SUMMARY OF BACKGROUND DATA: Anterior cervical plating is commonly used to increase stability and promote spinal fusion. Two techniques, fixed-hole dynamic plating that uses variable angled screws and slotted-hole dynamic plating that permits sliding, are viable options, but there have been no clinical studies comparing their effectiveness.
METHODS: Fifty-six patients at 1 institution having anterior cervical discectomy and fusion for degenerative disease over a 5-year period were entered into this study. Surgeries were performed with 1 of the dynamic plates for 1 to 3 levels. For the slotted-hole dynamic plate group, a slotted-hole plate was used (ABC, Aesculap, Tuttlingen, Germany or C-tek, Biomet, Parssipany, NJ) and for the fixed-hole dynamic plated group, a variable angled screw was used (C-tek, Biomet, Parssipany, NJ). Radiographic measurements included were graft subsidence, lordotic angle change from each end plate of fusion construct, and implant translation from end plates after a minimum of 12 months follow-up. Fusion state and clinical outcome using Odom's criteria were also evaluated.
RESULTS: Demographics were not different among patient populations. The average age of the patients was 51.0 years (range: 27 to 77 y). Mean follow-up period was 20.6 months (range: 12 to 41 mo). Slotted-hole dynamic plates were used for 29 patients (ABC plate, 17; C-tek plate, 12) and fixed-hole dynamic plates for 27 patients. Clinical outcomes and pseudoarthrosis rates were similar for both types of plates. Radiographic measurements showed a statistically significant increased incidence of graft subsidence and implant translation with the slotted-hole dynamic plates. Loss of lordosis was also greater in the slotted-hole dynamic plated group, although the difference was not statistically significant.
CONCLUSIONS: The use of a fixed-hole dynamic plate is more favorable in regards to graft subsidence and implant translation in the follow-up period, although clinical outcome and fusion rates are similar in patients with either the fixed-hole or slotted-hole dynamic plates.

Entities:  

Mesh:

Year:  2010        PMID: 20051923     DOI: 10.1097/BSD.0b013e31819877e7

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  3 in total

1.  Comparison between selective caudal fixed screw construct and all variable screw construct in anterior cervical discectomy and fusion.

Authors:  Jae Jun Yang; Sehan Park; Seongyun Park
Journal:  Sci Rep       Date:  2021-05-19       Impact factor: 4.379

2.  Clinical and radiological comparison of femur and fibular allografts for the treatment of cervical degenerative disc diseases.

Authors:  Hyeong-Seok Oh; Chan Shik Shim; Jin-Sung Kim; Sang-Ho Lee
Journal:  J Korean Neurosurg Soc       Date:  2013-01-31

3.  Operative outcomes for cervical myelopathy and radiculopathy.

Authors:  J G Galbraith; J S Butler; A M Dolan; J M O'Byrne
Journal:  Adv Orthop       Date:  2011-10-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.