Literature DB >> 20049955

Treatment of pulmonary vein stenosis with expanded polytetrafluoroethylene covered stents.

Brent M Gordon1, John W Moore.   

Abstract

Atrium expanded polytetrafluoroethylene covered stents were implanted in the stenotic pulmonary veins (n = 5) of three patients. Use of this device was feasible in infants and the procedure was well-tolerated without major complications. The majority (4/5) of covered stents remained patent for at least 3 months after implantation. Stents remain patent in the two surviving patients 6 months after deployment.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20049955     DOI: 10.1002/ccd.22240

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  Cryo-balloon angioplasty for pulmonary vein stenosis in pediatric patients.

Authors:  Michael A Bingler; Jeffrey R Darst; Thomas E Fagan
Journal:  Pediatr Cardiol       Date:  2011-09-03       Impact factor: 1.655

Review 2.  Management Of Pulmonary Vein Stenosis Following Catheter Ablation Of Atrial Fibrillation.

Authors:  Narendra Kumar; Ismail Aksoy; Laurent Pison; Carl Timmermans; Jos Maessen; Harry Crijns
Journal:  J Atr Fibrillation       Date:  2014-06-30
  2 in total