Literature DB >> 20049937

Quantification and characterization of subvisible proteinaceous particles in opalescent mAb formulations using micro-flow imaging.

Deepak K Sharma1, Peter Oma, Mark J Pollo, Muppalla Sukumar.   

Abstract

Micro-flow imaging (MFI) has been shown to be more sensitive than light obscuration (LO) methods for measuring subvisible proteinaceous particles in protein formulations. Given the potential challenges in detecting particulates in opalescent mAb formulations, the accuracy of MFI to size and count particles in opalescent solutions was investigated and compared to LO and membrane microscopy methods. Proteinaceous monoclonal antibody (mAb) particles, generated either by chemical denaturation or agitation stress, polystyrene and glass particles were used as model systems for measurements in opalescent mAb solutions. The sizing and counting accuracies of MFI were unaffected by the opalescence of the medium. Using glass particles as a model system for proteinaceous particles, MFI was able to detect relatively low particle concentrations (approximately 10/mL) in opalescent solutions. MFI showed excellent linearity (R(2) = 0.9969) for quantifying proteinaceous particles in opalescent solutions over a wide range of particle concentrations (approximately 20-160,000/mL). Analyses of MFI particle image intensities revealed significant differences in the transparency of proteinaceous particles as a function of their size and mode of generation. LO method significantly underestimated proteinaceous particles, particularly those in the 2-10 microm size range. The less opaque proteinaceous particles were relatively more underestimated by the LO method in opalescent solutions. (c) 2010 Wiley-Liss, Inc. and the American Pharmacists Association

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20049937     DOI: 10.1002/jps.22046

Source DB:  PubMed          Journal:  J Pharm Sci        ISSN: 0022-3549            Impact factor:   3.534


  14 in total

1.  Flow imaging microscopy for protein particle analysis--a comparative evaluation of four different analytical instruments.

Authors:  Sarah Zölls; Daniel Weinbuch; Michael Wiggenhorn; Gerhard Winter; Wolfgang Friess; Wim Jiskoot; Andrea Hawe
Journal:  AAPS J       Date:  2013-08-31       Impact factor: 4.009

Review 2.  Protein particulate detection issues in biotherapeutics development--current status.

Authors:  Tapan K Das
Journal:  AAPS PharmSciTech       Date:  2012-05-08       Impact factor: 3.246

3.  Structural characterization of IgG1 mAb aggregates and particles generated under various stress conditions.

Authors:  Srivalli N Telikepalli; Ozan S Kumru; Cavan Kalonia; Reza Esfandiary; Sangeeta B Joshi; C Russell Middaugh; David B Volkin
Journal:  J Pharm Sci       Date:  2014-01-22       Impact factor: 3.534

4.  Radar chart array analysis to visualize effects of formulation variables on IgG1 particle formation as measured by multiple analytical techniques.

Authors:  Cavan Kalonia; Ozan S Kumru; Jae Hyun Kim; C Russell Middaugh; David B Volkin
Journal:  J Pharm Sci       Date:  2013-10-09       Impact factor: 3.534

Review 5.  Structure, heterogeneity and developability assessment of therapeutic antibodies.

Authors:  Yingda Xu; Dongdong Wang; Bruce Mason; Tony Rossomando; Ning Li; Dingjiang Liu; Jason K Cheung; Wei Xu; Smita Raghava; Amit Katiyar; Christine Nowak; Tao Xiang; Diane D Dong; Joanne Sun; Alain Beck; Hongcheng Liu
Journal:  MAbs       Date:  2018-12-17       Impact factor: 5.857

Review 6.  Analytical comparability study of recombinant monoclonal antibody therapeutics.

Authors:  Alexandre Ambrogelly; Stephen Gozo; Amit Katiyar; Shara Dellatore; Yune Kune; Ram Bhat; Joanne Sun; Ning Li; Dongdong Wang; Christine Nowak; Alyssa Neill; Gomathinayagam Ponniah; Cory King; Bruce Mason; Alain Beck; Hongcheng Liu
Journal:  MAbs       Date:  2018-03-20       Impact factor: 5.857

Review 7.  Forced degradation of recombinant monoclonal antibodies: A practical guide.

Authors:  Christine Nowak; Jason K Cheung; Shara M Dellatore; Amit Katiyar; Ram Bhat; Joanne Sun; Gomathinayagam Ponniah; Alyssa Neill; Bruce Mason; Alain Beck; Hongcheng Liu
Journal:  MAbs       Date:  2017-08-30       Impact factor: 5.857

8.  Variable Threshold Method for Determining the Boundaries of Imaged Subvisible Particles.

Authors:  Richard E Cavicchi; Cayla Collett; Srivalli Telikepalli; Zhishang Hu; Michael Carrier; Dean C Ripple
Journal:  J Pharm Sci       Date:  2017-02-15       Impact factor: 3.534

9.  Micro-flow imaging: flow microscopy applied to sub-visible particulate analysis in protein formulations.

Authors:  Deepak K Sharma; Dave King; Peter Oma; Clark Merchant
Journal:  AAPS J       Date:  2010-06-02       Impact factor: 4.009

10.  Correcting the Relative Bias of Light Obscuration and Flow Imaging Particle Counters.

Authors:  Dean C Ripple; Zhishang Hu
Journal:  Pharm Res       Date:  2015-11-10       Impact factor: 4.200

View more