Abstract
Microparticles are released from the endothelium under normal homeostatic conditions and have been shown elevated in disease states, most notably those characterised by endothelial dysfunction. The endothelium is sensitive to oxidative stress/status and vascular cell adhesion molecule-1 (VCAM-1) expression is upregulated upon activated endothelium, furthermore the presence of VCAM-1 on microparticles is known. S100A12, a calcium binding protein part of the S100 family, is shown to be present on circulating leukocytes and is thought a sensitive marker to local inflammatory process, which may be driven by oxidative stress. Eight healthy males were subjected to breathing hypoxic air (15% O(2), approximately equivalent to 3000 metres altitude) for 80 minutes in a temperature controlled laboratory and venous blood samples were processed immediately for VCAM-1 microparticles (VCAM-1 MP) and S100A12 association with leukocytes by flow cytometry. A pre-hypoxic blood sample was used for comparison. Both VCAM-1 MP and S100A12 association with neutrophils were significantly elevated post hypoxic breathing later declining to levels observed in the pre-test samples. A similar trend was observed in both cases and a correlation may exist between these two markers in response to hypoxia. These data offer evidence using novel markers of endothelial and circulating blood responses to hypoxia.Entities:
Keywords: RAGE; S100A12; VCAM-1; endothelium; hypoxia; microparticles; oxidative stress
Mesh:
Substances:
Year: 2009 PMID: 20046638 PMCID: PMC2763224 DOI: 10.4161/oxim.2.1.7611
Source DB: PubMed Journal: Oxid Med Cell Longev ISSN: 1942-0994 Impact factor: 6.543
Figure 1Time dependent profile for VCAM+ MP and TBARS before and after hypoxic breathing. The data are represented as the mean and standard error of the mean (n = 8). HB = time during which subjects breathed hypoxic air.
Figure 2Typical flow cytometry profiles showing (top) forward scatter/side scatter with Netrophils and monocytes gated accordingly and (bottom) fluorescence profiles showing gated (black) neutrophils and (grey) monocytes incubated with either (filled) goat serum or (line) anti-human EN-RAGE.
Figure 3Time dependent profile for S100A12 expression on monocytes and neutrophils before and after hypoxic breathing. The data are represented as the mean and standard error of the mean (n = 8). HB = time during which subjects breathed hypoxic air.
Sequence of experimental events
| Time (h) | Experimental event |
| 07:15 | Subjects report to laboratory |
| 08:00 | Pre-hypoxia blood sample |
| 09:00 | Hypoxic breathing initiated |
| 10:20 | Hypoxic breathing ended |
| 11:00 | 1st post-exposure blood sample |
| 14:00 | 2nd post-exposure blood sample |
| 17:00 | 3rd post-exposure blood sample |
| 20:00 | 4th post-exposure blood sample |