Validity, reliability and reproducibility of three methods used to measure tooth widths for bolton analyses.

Devan Naidu1, Justin Scott, Desmond Ong, Christopher T C Ho.   

Abstract

BACKGROUND: Vernier calipers have traditionally been used as the 'gold-standard' for tooth width measurements. New digital methods may prove to be as valid, reliable and reproducible as caliper measurements. AIMS: To determine the validity, reliability and reproducibility of mesiodistal crown measurements made with calipers, using the DigiModel method and on digital photographs, and to determine the validity, reliability and reproducibility when the measurements are employed in Bolton tooth size analyses.
METHODS: Twenty-five consecutive study models were used. The maximum mesiodistal crown widths of 12 teeth in each arch (first molar to first molar) were measured with digital calipers, using the DigiModel software (OrthoProof, Caulfield South, Victoria, Australia) and on standardised digital photographs of the models by eight examiners. One examiner measured all models three times using the three measurement methods, two examiners measured all models once using the three measurement methods and five examiners measured all models once using the calipers only. Validity for the widths of individual teeth, the mean tooth width and the Bolton ratios were assessed using a general linear model two-way analysis of variance and pair-wise comparisons between the two digital methods and the calipers. Reliability was assessed with Cronbach's alpha and reproducibility with the intra-class correlation coefficient.
RESULTS: There were statistically significant differences between the tooth widths measured with DigiModel and the calipers (p < 0.001) and with the calipers and digital photographs (p < 0.001). However these discrepancies were judged not to be clinically significant. The Cronbach's alpha scores for all methods were classified as 'excellent'. The intra-class correlation coefficient values exceeded 0.75 for the digital calipers, 0.79 for DigiModel and 0.54 for the digital photographs.
CONCLUSIONS: The validities of DigiModel and digital photographs for tooth width measurements and Bolton analyses are clinically acceptable. The reliability of both methods is also excellent. However, DigiModel software provided more accurate Bolton's ratios and demonstrated greater reproducibility than the digital photographs.

Entities:  

Mesh:

Year:  2009        PMID: 20043542

Source DB:  PubMed          Journal:  Aust Orthod J        ISSN: 0587-3908


  15 in total

1.  Optical 3D scans for orthodontic diagnostics performed on full-arch impressions. Completeness of surface structure representation.

Authors:  Annike B Vogel; Fatih Kilic; Falko Schmidt; Sebastian Rübel; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2015-11       Impact factor: 1.938

2.  Comparison of orthodontic measurements on dental plaster casts and 3D scans.

Authors:  Johanna Radeke; Cynthia von der Wense; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2014-07-06       Impact factor: 1.938

3.  Dimensional accuracy of jaw scans performed on alginate impressions or stone models: A practice-oriented study.

Authors:  Annike B Vogel; Fatih Kilic; Falko Schmidt; Sebastian Rübel; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2015-07       Impact factor: 1.938

Review 4.  Linear measurements using virtual study models.

Authors:  Nghe S Luu; Liliya G Nikolcheva; Jean-Marc Retrouvey; Carlos Flores-Mir; Tarek El-Bialy; Jason P Carey; Paul W Major
Journal:  Angle Orthod       Date:  2012-04-24       Impact factor: 2.079

5.  Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography.

Authors:  Jooseong Kim; Giseon Heo; Manuel O Lagravère
Journal:  Angle Orthod       Date:  2013-08-19       Impact factor: 2.079

6.  Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis.

Authors:  Fan Zhang; Kyung-Jin Suh; Kyung-Min Lee
Journal:  PLoS One       Date:  2016-06-15       Impact factor: 3.240

7.  Evaluation of tip and torque on virtual study models: a validation study.

Authors:  Luis T Huanca Ghislanzoni; Megan Lineberger; Lucia H S Cevidanes; Andra Mapelli; Chiarella Sforza; James A McNamara
Journal:  Prog Orthod       Date:  2013-07-26       Impact factor: 2.750

8.  Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions.

Authors:  Tingting Jiang; Sang-Mi Lee; Yanan Hou; Xin Chang; Hyeon-Shik Hwang
Journal:  Korean J Orthod       Date:  2016-05-20       Impact factor: 1.372

9.  Reliability and validity of intraoral and extraoral scanners.

Authors:  Helder B Jacob; Graydon D Wyatt; Peter H Buschang
Journal:  Prog Orthod       Date:  2015-10-27       Impact factor: 2.750

10.  Dental measurements and Bolton index reliability and accuracy obtained from 2D digital, 3D segmented CBCT, and 3d intraoral laser scanner.

Authors:  Verónica San José; Carlos Bellot-Arcís; Beatriz Tarazona; Natalia Zamora; Manuel O Lagravère; Vanessa Paredes-Gallardo
Journal:  J Clin Exp Dent       Date:  2017-12-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.