Literature DB >> 20042989

Comparative utility of gated myocardial perfusion imaging and transthoracic coronary flow reserve for the assessment of coronary artery disease in patients with left bundle branch block.

Smiljana Pavlovic1, Dragana Sobic-Saranovic, Ana Djordjevic-Dikic, Branko Beleslin, Jelena Stepanovic, Vera Artiko, Vojislav Giga, Zorica Petrasinovic, Miodrag Ostojic, Bosiljka Vujisic-Tesic, Vladimir Obradovic.   

Abstract

OBJECTIVES: To compare the diagnostic utility of gated single-photon emission computed tomography (SPECT) methoxy isobutyl isonitrile (MIBI) myocardial perfusion imaging and transthoracic Doppler echocardiography (TTDE) coronary flow reserve (CFR) to coronary angiography for detecting coronary artery disease (CAD) in patients with left bundle branch block (LBBB).
METHOD: Forty-three patients with complete LBBB and an intermediate pretest probability for CAD underwent dipyridamole stress TTDE and gated SPECT MIBI during the same session and coronary angiography within a month. The parameters of myocardial perfusion (summed stress score, summed difference scores) regional wall function (wall motion score, wall thickening score) and ejection fraction were derived using the 17-segment model and 4D-MSPECT software. TTDE variables included peak flow velocity at rest and during hyperemia in left anterior descending artery (LAD), based on which CFR was calculated (normal>2).
RESULTS: Perfusion ischemic scores were significantly higher in group 1 with angiographic evidence of greater than 50% LAD stenosis compared with group 2 with less than 50% LAD stenosis (summed stress score 12.4+/-5.5 vs. 8.3+/-3.5, P<0.05, summed difference score 3.7+/-1.2 vs. 1.1+/-0.3, P<0.01, respectively). Left ventricular regional wall function and ejection fraction were not different between the two groups. CFR was significantly lower in group 1 than in group 2 (1.65+/-0.21 vs. 2.31+/-0.28, P<0.001). Gated SPECT MIBI and CFR had similar sensitivity (88 vs. 88%), specificity (80 vs. 84%), and accuracy (84 vs. 86%) for detecting CAD in patients with LBBB. The agreement between the two methods was 85%.
CONCLUSION: Our results show comparable diagnostic utility and high agreement between gated SPECT MIBI perfusion imaging and TTDE CFR assessment for detecting CAD in patients with LBBB. The advantage of gated SPECT MIBI over TTDE CFR measurements is the ability to assess the perfusion abnormalities in multiple vascular territories during the same procedure, which is convenient for detecting multi-vessel disease in patients with LBBB.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20042989     DOI: 10.1097/MNM.0b013e328335e5f2

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  1 in total

1.  Septal and anterior reverse mismatch of myocardial perfusion and metabolism in patients with coronary artery disease and left bundle branch block.

Authors:  Jian-Guang Wang; Wei Fang; Min-Fu Yang; Yue-Qin Tian; Xiao-Li Zhang; Rui Shen; Xiao-Xin Sun; Feng Guo; Dao-Yu Wang; Zuo-Xiang He
Journal:  Medicine (Baltimore)       Date:  2015-05       Impact factor: 1.889

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.