Literature DB >> 20037769

Topological optimization in hip prosthesis design.

M Fraldi1, L Esposito, G Perrella, A Cutolo, S C Cowin.   

Abstract

With particular interest on total hip arthroplasty (THA), optimization of orthopedic prostheses is employed in this work to minimize the probability of implant failure or maximize prosthesis reliability. This goal is often identified with the reduction of stress concentrations at the interface between bone and these devices. However, aseptic loosening of the implant is mainly influenced by bone resorption phenomena revealed in some regions of the femur when a prosthesis is introduced. As a consequence, bone resorption appears due to stress shielding, that is to say the decrease of the stress level in the implanted femur caused by the significant load carrying of the prosthesis due to its higher stiffness. A maximum stiffness topological optimization-based (TO) strategy is utilized for non-linear static finite element (FE) analyses of the femur-implant assembly, with the goal of reducing stress shielding in the femur and to furnish guidelines for re-designing hip prostheses. This is accomplished by employing an extreme accuracy for both the three- dimensional reconstruction of the femur geometry and the material properties maps assigned as explicit functions of the local densities.

Entities:  

Mesh:

Year:  2010        PMID: 20037769     DOI: 10.1007/s10237-009-0183-0

Source DB:  PubMed          Journal:  Biomech Model Mechanobiol        ISSN: 1617-7940


  8 in total

Review 1.  The paradox of Wolff's theories.

Authors:  A Hammer
Journal:  Ir J Med Sci       Date:  2014-01-29       Impact factor: 1.568

Review 2.  The advances of topology optimization techniques in orthopedic implants: A review.

Authors:  Naichao Wu; Shan Li; Boyan Zhang; Chenyu Wang; Bingpeng Chen; Qing Han; Jincheng Wang
Journal:  Med Biol Eng Comput       Date:  2021-08-07       Impact factor: 2.602

3.  Computational model for the patella onset.

Authors:  Kalenia Márquez-Flórez; Sandra Shefelbine; Angélica Ramírez-Martínez; Diego Garzón-Alvarado
Journal:  PLoS One       Date:  2018-12-11       Impact factor: 3.240

4.  Topology Optimisation for Compliant Hip Implant Design and Reduced Strain Shielding.

Authors:  Nathanael Tan; Richard J van Arkel
Journal:  Materials (Basel)       Date:  2021-11-25       Impact factor: 3.623

5.  Genetic-Based Optimization of 3D Burch-Schneider Cage With Functionally Graded Lattice Material.

Authors:  Manman Xu; Yan Zhang; Shuting Wang; Guozhang Jiang
Journal:  Front Bioeng Biotechnol       Date:  2022-01-26

Review 6.  Additive Manufacturing of Biomaterials-Design Principles and Their Implementation.

Authors:  Mohammad J Mirzaali; Vahid Moosabeiki; Seyed Mohammad Rajaai; Jie Zhou; Amir A Zadpoor
Journal:  Materials (Basel)       Date:  2022-08-08       Impact factor: 3.748

7.  A Novel Approach for Assessing the Fatigue Behavior of PEEK in a Physiologically Relevant Environment.

Authors:  Mirco Peron; Jan Torgersen; Filippo Berto
Journal:  Materials (Basel)       Date:  2018-10-10       Impact factor: 3.623

8.  Stress analysis in a bone fracture fixed with topology-optimised plates.

Authors:  Abdulsalam Abdulaziz Al-Tamimi; Carlos Quental; Joao Folgado; Chris Peach; Paulo Bartolo
Journal:  Biomech Model Mechanobiol       Date:  2019-10-24
  8 in total