Yanhong Sun1, Tang Jiang, Zhijie Zeng, Peisong Chen. 1. Department of Laboratory Medicine, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong, China.
Abstract
INTRODUCTION: Measurement of glomerular filtration rate (GFR) is critical for the diagnosis and stratification of chronic kidney disease (CKD). Recent studies have shown that cystatin C is superior to creatinine for the detection of impaired GFR, and several cystatin C-based equations for estimating GFR have been developed for this clinical application. We conducted the present study to assess the applicability of cystatin C as a routine clinical laboratory index and to determine the performance of cystatin C-based equations in estimating GFR in CKD patients in China. METHODS: Performance evaluation of particle-enhanced turbidimetric cystatin C assay on the Abbott Aeroset analyser was carried out according to the National Committee for Clinical Laboratory document EP10-A2. Estimated GFR, which was generated from cystatin C-based equations, was compared with measured GFR, which was detected by plasma clearance of 99mTc-DTPA. RESULTS: Our cystatin C assay showed a very low total imprecision and linearity drift. All eight cystatin C-based GFR estimating equations underestimated or overestimated GFR as compared with GFR determined by 99mTc-DTPA clearance. CONCLUSION: Although the cystatin C assay is acceptable for routine clinical laboratory monitoring, none of the existing cystatin C-based equations were ideal for estimating GFR in Chinese CKD patients.
INTRODUCTION: Measurement of glomerular filtration rate (GFR) is critical for the diagnosis and stratification of chronic kidney disease (CKD). Recent studies have shown that cystatin C is superior to creatinine for the detection of impaired GFR, and several cystatin C-based equations for estimating GFR have been developed for this clinical application. We conducted the present study to assess the applicability of cystatin C as a routine clinical laboratory index and to determine the performance of cystatin C-based equations in estimating GFR in CKDpatients in China. METHODS: Performance evaluation of particle-enhanced turbidimetric cystatin C assay on the Abbott Aeroset analyser was carried out according to the National Committee for Clinical Laboratory document EP10-A2. Estimated GFR, which was generated from cystatin C-based equations, was compared with measured GFR, which was detected by plasma clearance of 99mTc-DTPA. RESULTS: Our cystatin C assay showed a very low total imprecision and linearity drift. All eight cystatin C-based GFR estimating equations underestimated or overestimated GFR as compared with GFR determined by 99mTc-DTPA clearance. CONCLUSION: Although the cystatin C assay is acceptable for routine clinical laboratory monitoring, none of the existing cystatin C-based equations were ideal for estimating GFR in Chinese CKDpatients.
Authors: Almudena Vega; Soledad García de Vinuesa; Marian Goicoechea; Ursula Verdalles; María Luz Martínez-Pueyo; Ana Chacón; Borja Quiroga; José Luño Journal: Int Urol Nephrol Date: 2013-11-22 Impact factor: 2.370