Literature DB >> 20035178

Complications associated with negative pressure reaming for harvesting autologous bone graft: a case series.

Jason A Lowe1, Gregory J Della Rocca, Yvonne Murtha, Frank A Liporace, Michael D Stover, Sean E Nork, Brett D Crist.   

Abstract

A technical benefit of the reamer-irrigator-aspirator (RIA) system (Synthes, Paoli, PA) is the ability to harvest large volumes (40-90 cm3) of autogenous bone graft. Early evaluations of this technique have reported few problems, all of which were attributed to technical error. This case series reviews 6 RIA-associated complications including 4 fractures and their contributing risk factors. Cases were collected from 4 independent orthopaedic centers, and all patients underwent RIA bone graft harvesting in a lower extremity long bone injuries. In this population, 2 patients experienced acute RIA-associated events, necessitating an additional procedure or altered postoperative rehabilitation, whereas 4 patients fractured through their donor site in the early postoperative period. This series suggests that surgeons should (1) preoperatively assess cortical diameters at long bone harvest sites, (2) carefully monitor intraoperative reaming, and (3) avoid RIA bone graft harvesting in patients with a history of osteoporosis or osteopenia unless postharvest intramedullary stabilization is considered.

Entities:  

Mesh:

Year:  2010        PMID: 20035178     DOI: 10.1097/BOT.0b013e31819c0ccb

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  9 in total

Review 1.  Reamer-irrigator-aspirator indications and clinical results: a systematic review.

Authors:  George Cox; Elena Jones; Dennis McGonagle; Peter V Giannoudis
Journal:  Int Orthop       Date:  2011-01-18       Impact factor: 3.075

Review 2.  Treatment of critical-sized bone defects: clinical and tissue engineering perspectives.

Authors:  Erika Roddy; Malcolm R DeBaun; Adam Daoud-Gray; Yunzhi P Yang; Michael J Gardner
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-10-28

3.  [The reamer-irrigator-aspirator (RIA) System].

Authors:  R Pfeifer; P Kobbe; M Knobe; H-C Pape
Journal:  Oper Orthop Traumatol       Date:  2011-12       Impact factor: 1.154

Review 4.  Evaluation and management of atypical femoral fractures: an update of current knowledge.

Authors:  O Pearce; T Edwards; K Al-Hourani; M Kelly; A Riddick
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-02-15

Review 5.  Complications associated using the reamer-irrigator -aspirator (RIA) system: a systematic review and meta-analysis.

Authors:  Markus Laubach; Lucas P Weimer; Felix M Bläsius; Frank Hildebrand; Philipp Kobbe; Dietmar W Hutmacher
Journal:  Arch Orthop Trauma Surg       Date:  2022-09-17       Impact factor: 2.928

6.  More adverse events than expected in the outcome after use of the reamer-irrigator-aspirator.

Authors:  T S C Jakma; M A Röling; B Punt; P Reynders-Frederix
Journal:  Eur J Trauma Emerg Surg       Date:  2013-10-22       Impact factor: 3.693

Review 7.  The use of Reamer-irrigator-aspirator in the management of long bone osteomyelitis: an update.

Authors:  T H Tosounidis; G M Calori; P V Giannoudis
Journal:  Eur J Trauma Emerg Surg       Date:  2016-07-11       Impact factor: 3.693

8.  Fusion Revision Surgery With Reamer-Irrigator-Aspirator to Harvest Autograft After Spinal Pseudarthrosis.

Authors:  Ahmed H Elhessy; Hady H Eltayeby; Stephen C Kane; Ira M Garonzik; James E Conway; Janet D Conway
Journal:  Cureus       Date:  2022-07-31

9.  Complications and risk management in the use of the reaming-irrigator-aspirator (RIA) system: RIA is a safe and reliable method in harvesting autologous bone graft.

Authors:  Patrick Haubruck; Julian Ober; Raban Heller; Matthias Miska; Gerhard Schmidmaier; Michael C Tanner
Journal:  PLoS One       Date:  2018-04-26       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.