Literature DB >> 20034828

Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE.

Francisco Javier Casado1, Salvador García-Pareja, Elena Cenizo, Beatriz Mateo, Coral Bodineau, Pedro Galán.   

Abstract

Monte Carlo calculations are highly spread and settled practice to calculate brachytherapy sources dosimetric parameters. In this study, recommendations of the AAPM TG-43U1 report have been followed to characterize the Varisource VS2000 (192)Ir high dose rate source, provided by Varian Oncology Systems. In order to obtain dosimetric parameters for this source, Monte Carlo calculations with PENELOPE code have been carried out. TG-43 formalism parameters have been presented, i.e., air kerma strength, dose rate constant, radial dose function and anisotropy function. Besides, a 2D Cartesian coordinates dose rate in water table has been calculated. These quantities are compared to this source reference data, finding results in good agreement with them. The data in the present study complement published data in the next aspects: (i) TG-43U1 recommendations are followed regarding to phantom ambient conditions and to uncertainty analysis, including statistical (type A) and systematic (type B) contributions; (ii) PENELOPE code is benchmarked for this source; (iii) Monte Carlo calculation methodology differs from that usually published in the way to estimate absorbed dose, leaving out the track-length estimator; (iv) the results of the present work comply with the most recent AAPM and ESTRO physics committee recommendations about Monte Carlo techniques, in regards to dose rate uncertainty values and established differences between our results and reference data. The results stated in this paper provide a complete parameter collection, which can be used for dosimetric calculations as well as a means of comparison with other datasets from this source.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20034828     DOI: 10.1016/j.ejmp.2009.11.001

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  4 in total

1.  Therapeutic analysis of high-dose-rate (192)Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions.

Authors:  Hualin Zhang; Eric D Donnelly; Jonathan B Strauss; Yujin Qi
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

2.  Dosimetric investigation of a new high dose rate 192Ir brachytherapy source, IRAsource, by Monte Carlo method.

Authors:  Atefeh Rostami; Mahdi Hoseini; Mahdi Ghorbani; Courtney Knaup
Journal:  Rep Pract Oncol Radiother       Date:  2019-12-26

3.  Monte Carlo characterization of 169Yb as a high-dose-rate source for brachytherapy application by FLUKA code.

Authors:  Marzieh Anjomrouz; Mahdi Sadeghi; Asghar Haddadi
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

4.  Brachytherapy treatment planning commissioning: effect of the election of proper bibliography and finite size of TG-43 input data on standard treatments.

Authors:  Christian N Valdés; Gustavo H Píriz; Enrrique Lozano
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.