Literature DB >> 20034781

Magnetic beads based rolling circle amplification-electrochemiluminescence assay for highly sensitive detection of point mutation.

Qiang Su1, Da Xing, Xiaoming Zhou.   

Abstract

The identification of point mutations is particularly essential in the fields of medical diagnosis and prognosis of many pathogenic and genetic diseases. In this study, an rolling circle amplification (RCA) based electrochemiluminescence (ECL) assay for highly sensitive point mutation detection was developed. In the assay, an allele-discriminating padlock probe was designed for targeting the sequence in the p53 oncogene locus. A circular template generated by enzymatic ligation upon the recognition of a point mutation (CGT to CAT) on the oncogene could be amplified isothermally by Phi 29 DNA polymerase. The elongated products, containing hundreds of copies of the circular DNA template sequence, were hybridized with Ru(bpy)(3)(2+) (TBR)-tagged probes and then captured onto streptavidin-coated paramagnetic beads. The resulting products were analyzed by magnetic bead based ECL platform. As low as 2 amol of mutated strands was detected by this assay, which could be attributed to the high amplification efficiency of Phi 29 DNA polymerase and current magnetic bead based ECL detection platform. In addition, the positive mutation detection was achieved with a wild-type to mutant ratio of 10000:1, due to the high fidelity of DNA ligase in differentiating mismatched bases at the ligation site. It is demonstrated that this proposed method provides a highly sensitive and specific approach for point mutation detection. (c) 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20034781     DOI: 10.1016/j.bios.2009.11.025

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Detection of Prorocentrum minimum (Pavillard) Schiller with an electrochemiluminescence-molecular probe assay.

Authors:  Xia Zhu; Yu Zhen; Tiezhu Mi; Zhigang Yu
Journal:  Mar Biotechnol (NY)       Date:  2012-01-28       Impact factor: 3.619

Review 2.  Biosensors for hepatitis B virus detection.

Authors:  Chun-Yan Yao; Wei-Ling Fu
Journal:  World J Gastroenterol       Date:  2014-09-21       Impact factor: 5.742

3.  Design of Oligonucleotides for Allele-Specific Amplification Based on PCR and Isothermal Techniques.

Authors:  Luis Antonio Tortajada-Genaro
Journal:  Methods Mol Biol       Date:  2022

4.  Synthesis, labeling and bioanalytical applications of a tris(2,2'-bipyridyl)ruthenium(II)-based electrochemiluminescence probe.

Authors:  Xiaoming Zhou; Debin Zhu; Yuhui Liao; Weipeng Liu; Hongxing Liu; Zhaokui Ma; Da Xing
Journal:  Nat Protoc       Date:  2014-04-17       Impact factor: 13.491

Review 5.  Advances in ligase chain reaction and ligation-based amplifications for genotyping assays: Detection and applications.

Authors:  Abdullah A Gibriel; Ola Adel
Journal:  Mutat Res Rev Mutat Res       Date:  2017-05-02       Impact factor: 5.657

Review 6.  Diagnostic devices for isothermal nucleic acid amplification.

Authors:  Chia-Chen Chang; Chien-Cheng Chen; Shih-Chung Wei; Hui-Hsin Lu; Yang-Hung Liang; Chii-Wann Lin
Journal:  Sensors (Basel)       Date:  2012-06-14       Impact factor: 3.576

  6 in total