Literature DB >> 20033587

Improving education on C-arm operation and radiation protection with a computer-based training and simulation system.

Oliver Johannes Bott1, Markus Wagner, Christopher Duwenkamp, Nils Hellrung, Klaus Dresing.   

Abstract

PURPOSE: To discuss an approach to improve education in C-arm operation and reduction of radiation hazards based on a computer based training and simulation system called virtX.
METHODS: virtX is equipped with a visualization of scattered radiation and means to include patient positioning changes in radiograph simulation. virtX was integrated in a course for ORP and evaluated based on questionnaires.
RESULTS: Response rate was 73 (n = 77), mean age 35.4 (+/-9.2) and professional experience 11.2+/- 10.4 years. 91% use a C-arm regularly, 8% casually and 1% not. 78% agree that the translation of patient dummy positioning changes to simulated X-ray images is sufficiently realistic, 1% disagree (neutral 17%). 79% state that they acquired new knowledge concerning avoiding unnecessary radiation exposure, 10% do not (neutral 11%).
CONCLUSIONS: The virtX-approach of simulating radiograph generation including patient positioning and scattered radiation was evaluated positively concerning its suitability for imparting knowledge regarding radiation protection and C-arm operation.

Entities:  

Mesh:

Year:  2009        PMID: 20033587     DOI: 10.1007/s11548-009-0322-1

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  5 in total

Review 1.  Simulators in catheter-based interventional radiology: training or computer games?

Authors:  D A Gould; D O Kessel; A E Healey; S J Johnson; W E Lewandowski
Journal:  Clin Radiol       Date:  2006-07       Impact factor: 2.350

2.  virtX - evaluation of a computer-based training system for mobile C-arm systems in trauma and orthopedic surgery.

Authors:  O J Bott; M Teistler; C Duwenkamp; M Wagner; M Marschollek; M Plischke; B W Raab; K M Stürmer; D P Pretschner; K Dresing
Journal:  Methods Inf Med       Date:  2008       Impact factor: 2.176

3.  Measurement of the dose of radiation to the surgeon during surgery to the foot and ankle.

Authors:  P J Singh; N S Perera; R Dega
Journal:  J Bone Joint Surg Br       Date:  2007-08

4.  Increased cancer risk among surgeons in an orthopaedic hospital.

Authors:  Giuseppe Mastrangelo; Ugo Fedeli; Emanuela Fadda; Angelo Giovanazzi; Luca Scoizzato; Bruno Saia
Journal:  Occup Med (Lond)       Date:  2005-09       Impact factor: 1.611

Review 5.  A systematic review of medical skills laboratory training: where to from here?

Authors:  Marita Lynagh; Robert Burton; Rob Sanson-Fisher
Journal:  Med Educ       Date:  2007-08-13       Impact factor: 6.251

  5 in total
  5 in total

1.  [X-ray in trauma and orthopedic surgery. Physical and biological impact, reasonable use, and radiation protection in the operating room].

Authors:  K Dresing
Journal:  Oper Orthop Traumatol       Date:  2011-02       Impact factor: 1.154

2.  Seeing is believing: increasing intraoperative awareness to scattered radiation in interventional procedures by combining augmented reality, Monte Carlo simulations and wireless dosimeters.

Authors:  Nicolas Loy Rodas; Nicolas Padoy
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-02-26       Impact factor: 2.924

3.  The effect of artificial X-rays on C-arm positioning performance in a simulated orthopaedic surgical setting.

Authors:  Michèle Touchette; Robyn Newell; Carolyn Anglin; Pierre Guy; Kelly Lefaivre; Meena Amlani; Antony Hodgson
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-11-04       Impact factor: 2.924

4.  Real-time, ray casting-based scatter dose estimation for c-arm x-ray system.

Authors:  Zaid Alnewaini; Eric Langer; Philipp Schaber; Matthias David; Dominik Kretz; Volker Steil; Jürgen Hesser
Journal:  J Appl Clin Med Phys       Date:  2017-01-24       Impact factor: 2.102

5.  A Proposal for a Standardized Nomenclature of the C-arm Movements.

Authors:  D Alex Stroh; Aubrey Ashie; Paul Muccino; Chelsea Bush; Daniel Kaplan; Thomas DiPasquale
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2020-02-18
  5 in total