Prospective study of a 'popping' sound during percutaneous radiofrequency ablation for hepatocellular carcinoma.

Mark Lee Fernandes1, Chen-Chun Lin, Chun-Jung Lin, Wei-Ting Chen, Shi-Ming Lin.   

Abstract

PURPOSE: To prospectively evaluate the occurrence of a 'popping' sound during radiofrequency (RF) ablation for hepatocellular carcinoma (HCC) and its association with early tumor progression and patient survival.
MATERIALS AND METHODS: Seventy-six patients with 100 tumors underwent RF ablation by using an internally cooled electrode. A popping sound was defined as an audible sound or tactile vibration detected by the operator during RF ablation. Follow-up ranged from 6 to 38 months (mean, 19 months) and included 3-6 month ultrasonography, serum alpha-fetoprotein measurements, and computed tomography or magnetic resonance imaging. Early local and distant intrahepatic tumor progression within 12 months and survival were analyzed.
RESULTS: A popping sound occurred during 58 of the 100 (58%) tumor ablations. Primary technique effectiveness was achieved in 97 of the 100 (97%) tumors. Major complications occurred in 2 of the 76 patients (2.6%). The cumulative rate of early local tumor progression was 20.8%. At multivariate analysis, early local tumor progression was associated with tumor size larger than 3 cm (odds ratio [OR] = 4.08, P = .012) and inversely associated with a popping sound (OR = 0.267, P = .026). The cumulative rate of early distant intrahepatic tumor progression was 21.4%, and the cumulative survival of the whole cohort at 6, 12, 18, and 24 months was 98.7%, 96%, 92.7%, and 83.6%, respectively. A popping sound was not significantly associated with either early distant intrahepatic tumor progression (P = .341) or patient survival (P = .975).
CONCLUSIONS: A popping sound during RF ablation is not associated with an increased risk of early tumor progression or poorer patient survival. Copyright (c) 2010 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20031448     DOI: 10.1016/j.jvir.2009.10.015

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  5 in total

Review 1.  Local ablation for hepatocellular carcinoma in taiwan.

Authors:  Shi-Ming Lin
Journal:  Liver Cancer       Date:  2013-04       Impact factor: 11.740

2.  Effectiveness of impedance monitoring during radiofrequency ablation for predicting popping.

Authors:  Hiroya Iida; Tsukasa Aihara; Shinichi Ikuta; Naoki Yamanaka
Journal:  World J Gastroenterol       Date:  2012-11-07       Impact factor: 5.742

3.  Measurement of Intrahepatic Pressure during Microwave Ablation in an Ex Vivo Bovine Liver Model.

Authors:  Hae Jin Kim; Hyunchul Rhim; Min Woo Lee; Woo Kyoung Jeong
Journal:  Gut Liver       Date:  2015-11-23       Impact factor: 4.519

4.  Effect of Perfluorobutane Microbubbles on Radiofrequency Ablation for Hepatocellular Carcinoma: Suppression of Steam Popping and Its Clinical Implication.

Authors:  Dong Young Jeong; Tae Wook Kang; Ji Hye Min; Kyoung Doo Song; Min Woo Lee; Hyunchul Rhim; Hyo Keun Lim; Dong Hyun Sinn; Heewon Han
Journal:  Korean J Radiol       Date:  2020-09       Impact factor: 3.500

5.  Real-Time Internal Steam Pop Detection during Radiofrequency Ablation with a Radiofrequency Ablation Needle Integrated with a Temperature and Pressure Sensor: Preclinical and Clinical Pilot Tests.

Authors:  Jaeho Park; Dong Ik Cha; Yongrok Jeong; Hayan Park; Jinwoo Lee; Tae Wook Kang; Hyo Keun Lim; Inkyu Park
Journal:  Adv Sci (Weinh)       Date:  2021-08-05       Impact factor: 16.806

  5 in total