Removal of ring artifacts in computed tomographic imaging using iterative center weighted median filter.

Fazle Sadi1, Soo Yeol Lee, Md Kamrul Hasan.   

Abstract

A new iterative center weighted median filter (ICWMF) for ring artifact reduction from the micro-computed tomographic (micro-CT) image is proposed in this paper. The center weight of the median filter is computed based on the characteristic of the ring artifact in the mean curve of the projection data. The filter operates on the deviation of the mean curve to smooth the ring generating peaks and troughs iteratively while preserving the details due to image. A convergence criterion for the iterative algorithm is determined from the distribution of the local deviation computed from the mean curve deviation. The estimate of the mean curve obtained using the ICWMF is used to correct the ring corrupted projection data from which reconstruction gives the ring artifact suppressed micro-CT image. Test results on both the synthetic and real images demonstrate that the ring artifacts can be more effectively suppressed using our method as compared to other ring removal techniques reported in the literature. 2009 Elsevier Ltd. All rights reserved.

Mesh:

Year:  2009        PMID: 20031123     DOI: 10.1016/j.compbiomed.2009.11.007

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  6 in total

1.  Improved tomographic reconstructions using adaptive time-dependent intensity normalization.

Authors:  Valeriy Titarenko; Sofya Titarenko; Philip J Withers; Francesco De Carlo; Xianghui Xiao
Journal:  J Synchrotron Radiat       Date:  2010-07-22       Impact factor: 2.616

2.  A novel total variation based ring artifact suppression method for CBCT imaging with two-dimensional antiscatter grids.

Authors:  Timur Alexeev; Brian Kavanagh; Moyed Miften; Cem Altunbas
Journal:  Med Phys       Date:  2019-03-20       Impact factor: 4.071

3.  Comparison of ring artifact removal methods using flat panel detector based CT images.

Authors:  Emran M Abu Anas; Jae G Kim; Soo Y Lee; K Hasan
Journal:  Biomed Eng Online       Date:  2011-08-17       Impact factor: 2.819

4.  A Ring Artifact Correction Method: Validation by Micro-CT Imaging with Flat-Panel Detectors and a 2D Photon-Counting Detector.

Authors:  Mohamed Elsayed Eldib; Mohamed Hegazy; Yang Ji Mun; Myung Hye Cho; Min Hyoung Cho; Soo Yeol Lee
Journal:  Sensors (Basel)       Date:  2017-01-30       Impact factor: 3.576

5.  Complete Ring Artifacts Reduction Procedure for Lab-Based X-ray Nano CT Systems.

Authors:  Jakub Šalplachta; Tomáš Zikmund; Marek Zemek; Adam Břínek; Yoshihiro Takeda; Kazuhiko Omote; Jozef Kaiser
Journal:  Sensors (Basel)       Date:  2021-01-01       Impact factor: 3.576

6.  COVID-19 CT image denoising algorithm based on adaptive threshold and optimized weighted median filter.

Authors:  Shuli Guo; Guowei Wang; Lina Han; Xiaowei Song; Wentao Yang
Journal:  Biomed Signal Process Control       Date:  2022-02-16       Impact factor: 5.076

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.