Microhardness of glass ionomer cements indicated for the ART technique according to surface protection treatment and storage time.

Luciana Keiko Shintome1, Marcos Paulo Nagayassu, Rebeca Di Nicoló, Silvio Issáo Myaki.   

Abstract

The aim of this study was to assess the microhardness of 5 glass ionomer cements (GIC) - Vidrion R (V, SS White), Fuji IX (F, GC Corp.), Magic Glass ART (MG, Vigodent), Maxxion R (MR, FGM) and ChemFlex (CF, Dentsply) - in the presence or absence of a surface protection treatment, and after different storage periods. For each GIC, 36 test specimens were made, divided into 3 groups according to the surface protection treatment applied - no protection, varnish or nail varnish. The specimens were stored in distilled water for 24 h, 7 and 30 days and the microhardness tests were performed at these times. The data obtained were submitted to the ANOVA for repeated measures and Tukey tests (alpha = 5%). The results revealed that the mean microhardness values of the GICs were, in decreasing order, as follows: F > CF = MR > MG > V; that surface protection was significant for MR, at 24 h, without protection (64.2 + or - 3.6a), protected with GIC varnish (59.6 + or - 3.4b) and protected with nail varnish (62.7 + or - 2.8ab); for F, at 7 days, without protection (97.8 + or - 3.7ab), protected with varnish (95.9 + or - 3.2b) and protected with nail varnish (100.8 + or - 3.4a); and at 30 days, for F, without protection (98.8 + or - 2.6b), protected with varnish (103.3 + or - 4.4a) and protected with nail varnish (101 + or - 4.1ab) and, for V, without protection (46 + or - 1.3b), protected with varnish (49.6 + or - 1.7ab) and protected with nail varnish (51.1 + or - 2.6a). The increase in storage time produced an increase in microhardness. It was concluded that the different GICs, surface protection treatments and storage times could alter the microhardness values.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20027452     DOI: 10.1590/s1806-83242009000400014

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  5 in total

1.  Surface roughness of glass ionomer cements indicated for uncooperative patients according to surface protection treatment.

Authors:  Edoardo Pacifici; Maurizio Bossù; Agostino Giovannetti; Giuseppe La Torre; Fabrizio Guerra; Antonella Polimeni
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

2.  Effect of antibacterial agents on the surface hardness of a conventional glass-ionomer cement.

Authors:  Tamer Tüzüner; Tezer Ulusu
Journal:  J Appl Oral Sci       Date:  2012-02       Impact factor: 2.698

3.  Comparative Evaluation of the Mechanical Properties of Zinc-reinforced Glass Ionomer Cement and Glass Ionomer Type IX Cement: An In Vitro Study.

Authors:  Krishna Patil; Alok Patel; Sanket Kunte; Preetam Shah; Buneet Kaur; Sujatha Paranna
Journal:  Int J Clin Pediatr Dent       Date:  2020 Jul-Aug

Review 4.  Twenty-five-year atraumatic restorative treatment (ART) approach: a comprehensive overview.

Authors:  Jo E Frencken; Soraya Coelho Leal; Maria Fidela Navarro
Journal:  Clin Oral Investig       Date:  2012-07-24       Impact factor: 3.573

5.  Mechanical Properties of High Viscosity Glass Ionomer and Glass Hybrid Restorative Materials.

Authors:  Ivan Šalinović; Matea Stunja; Zdravko Schauperl; Željko Verzak; Ana Ivanišević Malčić; Valentina Brzović Rajić
Journal:  Acta Stomatol Croat       Date:  2019-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.