Literature DB >> 20026023

Direct measurement of serum free testosterone by ultrafiltration followed by liquid chromatography tandem mass spectrometry.

Yu Chen1, Mehrdad Yazdanpanah, Xiao Yan Wang, Barry R Hoffman, Eleftherios P Diamandis, Pui-Yuen Wong.   

Abstract

BACKGROUND: Currently there is no reliable method suitable for routine measurement of serum free testosterone (FT). AIM: To develop such a method involving liquid chromatography tandem mass spectrometry (LC-IDMS/MS) that directly detects and quantifies the FT present in serum.
METHODS: Ultrafiltrate testosterone obtained from 0.5 mL of serum was partially purified by liquid/liquid extraction and quantified using an Agilent 1200 Series HPLC system coupled to an API 5000 mass spectrometer equipped with an atmospheric pressure chemical ionization ion source. Using split samples serum free testosterone was compared between direct ultrafiltration (UF) coupled LC-MS/MS, analogue FT immunoassay, free testosterone calculated from mass action equations (cFT) and with equilibrium dialysis (ED) coupled LC-MS/MS.
RESULTS: Total imprecision determined over twenty runs was <6% at 67 pmol/L and 158 pmol/L FT. The dynamic response was linear up to at least 2500 pmol/L while physical LLOQ (18 % CV) equaled 16 pmol/L. The UF method agreed poorly with analogue immunoassay (correlation coefficient 0.667; bias -81%), somewhat better against cFT when total testosterone was determined by immunoassay (correlation coefficient 0.816, bias 21% ) and still better yet against cFT when total testosterone was determined by LC-MS/MS (correlation coefficient 0.8996, bias 10%). Agreement was closest with ED method (correlation coefficient 0.9779, bias 2.4%).
CONCLUSION: We present a relatively simple UF coupled LC-MS/MS definitive method that measures serum free testosterone. The method is relatively fast, reliable and is suitable for the routine clinical laboratory practice. Copyright 2009 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20026023     DOI: 10.1016/j.clinbiochem.2009.12.005

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  7 in total

Review 1.  Importance of hypogonadism and testosterone replacement therapy in current urologic practice: a review.

Authors:  Wayne J G Hellstrom; Darius Paduch; Craig F Donatucci
Journal:  Int Urol Nephrol       Date:  2010-12-09       Impact factor: 2.370

2.  Performance evaluation of Siemens ADVIA Centaur and Roche MODULAR Analytics E170 Total 25-OH Vitamin D assays.

Authors:  Yu Chen; Lois Kinney; Andrea Božović; Hilary Smith; Heather Tarr; Eleftherios P Diamandis; Adrien LeBlanc
Journal:  Clin Biochem       Date:  2012-06-13       Impact factor: 3.281

3.  Long-duration space flight and bed rest effects on testosterone and other steroids.

Authors:  Scott M Smith; Martina Heer; Zuwei Wang; Carolyn L Huntoon; Sara R Zwart
Journal:  J Clin Endocrinol Metab       Date:  2011-11-02       Impact factor: 5.958

4.  Bone density in haemophilia: a single institutional cross-sectional study.

Authors:  C L Kempton; A Antun; D M Antoniucci; W Carpenter; M Ribeiro; S Stein; L Slovensky; L Elon
Journal:  Haemophilia       Date:  2013-08-01       Impact factor: 4.287

Review 5.  Role of sex hormone-binding globulin in the free hormone hypothesis and the relevance of free testosterone in androgen physiology.

Authors:  L Antonio; D Vanderschueren; N Narinx; K David; J Walravens; P Vermeersch; F Claessens; T Fiers; B Lapauw
Journal:  Cell Mol Life Sci       Date:  2022-10-07       Impact factor: 9.207

6.  Revisiting hyper- and hypo-androgenism by tandem mass spectrometry.

Authors:  Flaminia Fanelli; Alessandra Gambineri; Marco Mezzullo; Valentina Vicennati; Carla Pelusi; Renato Pasquali; Uberto Pagotto
Journal:  Rev Endocr Metab Disord       Date:  2013-06       Impact factor: 6.514

7.  Effect of sex and prior exposure to a cafeteria diet on the distribution of sex hormones between plasma and blood cells.

Authors:  María Del Mar Romero; José Antonio Fernández-López; Xavier Remesar; Marià Alemany
Journal:  PLoS One       Date:  2012-03-27       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.