Literature DB >> 20025531

Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers.

Guillaume Kac1, Isabelle Podglajen, Ali Si-Mohamed, Aurelia Rodi, Christine Grataloup, Guy Meyer.   

Abstract

OBJECTIVE: To determine the rate of bacterial and viral contamination of endocavitary ultrasound probes after endorectal or endovaginal examination with the use of probe covers and to evaluate the antimicrobial efficacy of a disinfection procedure consisting of cleaning with a disinfectant-impregnated towel followed by disinfection with ultraviolet C (UVC) light.
METHODS: Endovaginal or endorectal ultrasound examinations were performed for 440 patients in 3 institutions. All probes were covered by a condom or sheath during the examination. For bacterial analysis, 1 swab was applied lengthwise across one-half the surface of the probe just after removal of the probe cover. The second swab was similarly applied over the probe immediately after the end of a 2-step process consisting of cleaning with a towel impregnated with a disinfectant spray and a 5-minute UVC disinfection cycle. Swabs were applied onto plates and incubated for 48 hours. The number of colony-forming units was counted, and organisms were identified. A similar protocol was used for viral detection of Epstein-Barr virus, human cytomegalovirus, and human papillomavirus, except that an additional swab was applied along the entire external surface of the probe cover before its removal. Viruses were detected by means of a polymerase chain reaction-based protocol.
RESULTS: After removal of probe covers, contamination by pathogenic bacteria was found for 15 (3.4% [95% confidence interval, 2.0%-5.6%]) of 440 probes, and viral genome was detected on 5 (1.5% [95% confidence interval, 0.5%-3.5%]) of 336 probes. After cleaning with a towel impregnated with a disinfectant spray and disinfecting with UVC light, neither bacterial pathogenic flora nor viral genome was recovered from the probe.
CONCLUSIONS: Endocavitary ultrasound probes may carry pathogens after removal of covers under routine conditions. A disinfection procedure consisting of cleaning with a disinfectant-impregnated towel followed by disinfection with UVC may provide a useful method for disinfecting endocavitary ultrasound probes.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20025531     DOI: 10.1086/649794

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  14 in total

Review 1.  Ultrasound-guided central vascular interventions, comments on the European Federation of Societies for Ultrasound in Medicine and Biology guidelines on interventional ultrasound.

Authors:  Christoph F Dietrich; Rudolf Horn; Susanne Morf; Liliana Chiorean; Yi Dong; Xin-Wu Cui; Nathan S S Atkinson; Christian Jenssen
Journal:  J Thorac Dis       Date:  2016-09       Impact factor: 2.895

2.  Advancing infection control in Australasian medical ultrasound practice.

Authors:  Susan Campbell Westerway; Jocelyne M Basseal
Journal:  Australas J Ultrasound Med       Date:  2017-02-23

3.  Occupational exposure of oropharyngeal human papillomavirus amongst otolaryngologists.

Authors:  Rahul S Subbarayan; Matthew Shew; Jonathan Enders; Andrés M Bur; Sufi M Thomas
Journal:  Laryngoscope       Date:  2019-11-11       Impact factor: 3.325

4.  Decontamination of targeted pathogens from patient rooms using an automated ultraviolet-C-emitting device.

Authors:  Deverick J Anderson; Maria F Gergen; Emily Smathers; Daniel J Sexton; Luke F Chen; David J Weber; William A Rutala
Journal:  Infect Control Hosp Epidemiol       Date:  2013-05       Impact factor: 3.254

5.  Complete sequencing of pNDM-HK encoding NDM-1 carbapenemase from a multidrug-resistant Escherichia coli strain isolated in Hong Kong.

Authors:  Pak Leung Ho; Wai U Lo; Man Kiu Yeung; Chi Ho Lin; Kin Hung Chow; Irene Ang; Amy Hin Yan Tong; Jessie Yun-Juan Bao; Si Lok; Janice Yee Chi Lo
Journal:  PLoS One       Date:  2011-03-21       Impact factor: 3.240

6.  UVC radiation as an effective disinfectant method to inactivate human papillomaviruses.

Authors:  Craig Meyers; Janice Milici; Richard Robison
Journal:  PLoS One       Date:  2017-10-31       Impact factor: 3.240

7.  High risk HPV contamination of endocavity vaginal ultrasound probes: an underestimated route of nosocomial infection?

Authors:  Jean-sebastien Casalegno; Karine Le Bail Carval; Daniel Eibach; Marie-Laure Valdeyron; Gery Lamblin; Hervé Jacquemoud; Georges Mellier; Bruno Lina; Pascal Gaucherand; Patrice Mathevet; Yahia Mekki
Journal:  PLoS One       Date:  2012-10-24       Impact factor: 3.240

8.  Persistence of microbial contamination on transvaginal ultrasound probes despite low-level disinfection procedure.

Authors:  Fatima M'Zali; Carole Bounizra; Sandrine Leroy; Yahia Mekki; Claudine Quentin-Noury; Michael Kann
Journal:  PLoS One       Date:  2014-04-02       Impact factor: 3.240

Review 9.  Emergency department ultrasound probe infection control: challenges and solutions.

Authors:  Hamid Shokoohi; Paige Armstrong; Ryan Tansek
Journal:  Open Access Emerg Med       Date:  2015-01-05

Review 10.  Ultrasound scan as a potential source of nosocomial and crossinfection: a literature review.

Authors:  André Hadyme Miyague; Fernando Marum Mauad; Wellington de Paula Martins; Augusto César Garcia Benedetti; Ana Elizabeth Gomes de Melo Tavares Ferreira; Francisco Mauad-Filho
Journal:  Radiol Bras       Date:  2015 Sep-Oct
View more