Literature DB >> 2002531

Warning: fatal reaction to the use of fibrin glue in deep hepatic wounds. Case reports.

R Berguer1, R L Staerkel, E E Moore, F A Moore, W B Galloway, M B Mockus.   

Abstract

Two cases of severe hypotension following the use of fibrin glue for hemostasis in hepatic injuries are reported. A systemic reaction to bovine thrombin via large venous lacerations is suspected. A preliminary animal study supports this hypothesis. Caution is advised in the use of fibrin glue for hemostasis in deep hepatic wounds.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2002531

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  8 in total

1.  Continuing evolution in the approach to severe liver trauma.

Authors:  D V Feliciano
Journal:  Ann Surg       Date:  1992-11       Impact factor: 12.969

Review 2.  Polymeric materials for embolic and chemoembolic applications.

Authors:  Azadeh Poursaid; Mark Martin Jensen; Eugene Huo; Hamidreza Ghandehari
Journal:  J Control Release       Date:  2016-02-26       Impact factor: 9.776

3.  Preparation of a pure autologous biodegradable fibrin matrix for tissue engineering.

Authors:  A Haisch; A Loch; J David; A Pruss; R Hansen; M Sittinger
Journal:  Med Biol Eng Comput       Date:  2000-11       Impact factor: 2.602

4.  Arrest of liver haemorrhage secondary to percutaneous liver biopsy of a haemangioma with fibrin glue.

Authors:  Elijah Dixon; Janice L Pasieka
Journal:  HPB (Oxford)       Date:  2002       Impact factor: 3.647

5.  Fibrin glue eliminates the need for packing after complex liver injuries.

Authors:  A J Feinstein; J E Varela; S M Cohn; R P Compton; M G McKenney
Journal:  Yale J Biol Med       Date:  2001 Sep-Oct

Review 6.  Fibrin glue in ophthalmology.

Authors:  Anita Panda; Sandeep Kumar; Abhiyan Kumar; Raseena Bansal; Shibal Bhartiya
Journal:  Indian J Ophthalmol       Date:  2009 Sep-Oct       Impact factor: 1.848

7.  Risk of bleeding in surgical patients treated with topical bovine thrombin sealants: a review of the literature.

Authors:  Matthew W Reynolds; John Clark; Sheila Crean; Srinath Samudrala
Journal:  Patient Saf Surg       Date:  2008-03-18

8.  Fibrin sealant does not decrease seroma output or time to drain removal following inguino-femoral lymph node dissection in melanoma patients: a randomized controlled trial (NCT00506311).

Authors:  Melinda M Mortenson; Yan Xing; Storm Weaver; Jeffrey E Lee; Jeffrey E Gershenwald; Anthony Lucci; Paul F Mansfield; Merrick I Ross; Janice N Cormier
Journal:  World J Surg Oncol       Date:  2008-06-18       Impact factor: 2.754

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.